Draeger X-act® 7000

Draeger X-act® 7000

Draeger Micro Tubes for the X-act® 7000

$0.00
SKU
DRA-Micro-Tubes

Draeger X-act® 7000 Micro-Tubes - 

The Draeger X-act® 7000 with Draeger Micro-Tubes is an analysis system that is immediately ready for use. Simply insert the right Draeger MicroTube for your testing needs into the Draeger X-act® 7000. The automatic drive carefully draws the MicroTube in and positions it. Control your test using the 3-button control and 2.4 inch colour display. When the test is complete, the green LED will glow and a message is displayed on the screen. You can store the test result, location and time in the internal data logger and read it later using the Draeger CC Vision software. The device is powered by five easily replaceable AA alkaline batteries. The battery life lasts for more than ten hours of testing and can be read on the display.

10 Measurements per pack, Sold by the pack.

 *The Draeger X-act 7000 unit is sold separately.

Available Micro-Tubes for the Draeger X-act® 7000-

Specifications
Description Test Range Test Time (min-max) Part Number/Tube-Specs
Acetone 25 – 5,000 ppm 20 – 500 seconds 8610470
Alcohol (Methanol) 10 – 5,000 ppm 20 – 450 seconds 8610380
Alcohol (Ethanol) 5 – 2,500 ppm 20 – 450 seconds 8610380
Alcohol (i-Propanol) 10 – 5,000 ppm 20 – 450 seconds 8610380
Alcohol (n-Butanol) 7 – 3,330 ppm 20 – 450 seconds 8610380
Ammonia 1 – 100 ppm 10 – 75 seconds 8610130
Ammonia 100 – 2,500 ppm 3 – 45 seconds 8610020
Benzene 1 – 150 ppb 100 – 900 seconds 8610600
Benzene 0.15 – 10 ppm 25 – 150 seconds 8610030
Benzene 10 - 100 ppm 10 - 75 seconds 8610280
1,3-Butadiene 25 – 500 ppb 200 – 600 seconds 8610460
1,3-Butadiene 0.5 – 25 ppm 10 – 280 seconds 8610300
Carbon Dioxide 200 – 50,000 ppm 2 – 120 seconds 8610190
Carbon Monoxide 2 – 1,000 ppm 5 – 300 seconds 8610080
Chlorine 50 – 5,000 ppb 10 – 400 seconds 8610010
Demo NA approx. 30 seconds 8610290
Ethylene Oxide 25 – 250 ppb 150 – 600 seconds 8610200
Ethylene Oxide 0.25 – 10 ppm 100 – 500 seconds 8610580
Formaldehyde 5 – 150 ppb 360 – 960 seconds 8610540
Formaldehyde 0.15 – 3 ppm 300 – 600 seconds 8610100
Hydrochloric Acid 0.5 – 25 ppm 10 – 100 seconds 8610090
Hydrocyanic Acid 0.5 – 50 ppm 20 – 180 seconds 8610520
Hydrogen Sulfide 0.1 – 50 ppm 5 – 960 seconds 8610050
Hydrogen Sulfide 100 - 2,000 ppm 15 - 180 seconds 8610220
Mercaptan 50 – 6,000 ppb 15 – 360 seconds 8610360
Mercury 0.005 – 0.25 mg/m3 240 – 1,200 seconds 8610350
MTBE 2 - 200 ppm 60 - 450 seconds 8610530
Nitrogen Dioxide 0.25 – 50 ppm 10 – 210 seconds 8610120
Nitrous Fumes 10 – 1,000 ppm 10 – 240 seconds 8610260
Ozone 10 - 1,000 ppb 50 - 840 seconds 8610430
Perchloroethylene 1 – 500 ppm 25 – 240 seconds 8610040
Petroleum Hydrocarbons 10 – 3,000 ppm 10 – 360 seconds 8610270
Phosgene 10 – 1,000 ppb 10 – 300 seconds 8610340
Sulfur Dioxide 0.05 – 5 ppm 20 – 480 seconds 8610110
Toluene 10 – 1,000 ppm 6 – 360 seconds 8610250
Trichloroethylene 0.25 - 50 ppm 20 - 270 seconds 8610320
Xylene 10 – 1,000 ppm 10 – 240 seconds 8610260


MicroTube Alcohol (8610380) Methanol is the calibration substance. Other alcohols are displayed with the following sensitivity:
*Ethanol with twice the sensitivity: Indication in the display ÷ 2 = ppm ethanol (applies to the measuring range 5 – 2,500 ppm ethanol)
*i-Propanol with the same sensitivity: Display = ppm i-propanol (applies to the measuring range 10 – 5,000 ppm i-propanol)
*n-Butanol with one and a half times sensitivity: Indication in display ÷ 1.5 = ppm n-butanol (applies to the measuring range approx. 7 – 3,300 ppm n-Butanol)