Draeger X-am® 2800 Multi-Gas Monitors

Draeger X-am® 2800 Multi-Gas Monitors

Draeger X-am® 2500 Multi-Gas Monitors

$0.00
SKU
Draeger-X-am-2500

Draeger X-am® 2500 Multi-Gas Monitors - 

The Draeger X-am® 2500- Draeger’s X-am® 2500 accurately detects O2, CO, NO2, SO2 and H2S and is the only 1-4 gas monitor you need in industrial and refinery applications. The X-am® 2500 combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety. The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. Further, the X-am 2500 is approved for measuring from methane to nonane, according to IEC/EN 60079-29-1.

The Draeger X-am® 2500 has an optional external pump with a hose up to 45 m / 147 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws. Which is best of both worlds in gas detection!

Draeger X-am® 2500 Literature

– Measures the following:
      (CO) - Carbon Monoxide
      (H2S) - Hydrogen Sulfide
      (Methane) - UL/CSA Combustible %LEL / %VOL (%VOL ranges setup in CC Vision software)
      (Methane) - MSHA Combustible %VOL (%VOL ranges setup in CC Vision software)
      (O2) - Oxygen
      (SO2) - Sulfur Dioxide
      (NO2) - Nitrogen Dioxide

- User Configurable settings with CC-Vision Software by Draeger

- Price breaks for orders in quantities of 10/ 50/ 100 / 200 / 500

 

Monitor Only Includes:

- Monitor with Selected Sensor

- Diffusion or Pumped Model

- Battery as specified

- Charger Assy not included unless selected with Charging Kit.

- Calibration Certificate

- Manual / Guide

 

Pump Kit(s) Options:

- Basic Pump Kit comes with: Pump with USB Charger , Wall Plug and Shoulder Strap

- CSE Pump Kit comes with: Pump with USB Cable, Wall Plug, 5m of FKM hose, Float Probe, Shoulder Strap and Pump Kit Case

 

Calibration Kit Includes / Adds:

- Stainless Steel Regulator(s) depending upon gas selection

- 34/58/116 Liter Cylinders Calibration Gases (specifc gases per selected sensor(s)

- 4 Gas Mix = CO, H2S, LEL -Methane, O2, Bal N2.

- Draeger Calibration / Communication Cradle (without IR-USB)

 *(please note we offer other calibration kits depending upon sensor configuration on monitor)

 

Optional Protective Cases / Adds:

- Draeger Custom Foam Cut Case

- Pelican Case - Airtight / Waterproof / Dustproof with Pick n Pluck Foam - Colors may Vary.

Draeger X-am® 2500 Sensor Specifications

Specifications
Description Mesuring Range Alarm Threshold A1/A2 (standard) Measuring Resolution Sensor Order Number
Draeger X-am® 2500 Carbon Monoxide - CO 0-2000ppm 35 / 50ppm 1ppm  6813210
Draeger X-am® 2500 Hydrogen Sulfide - H2S 0-100ppm  10 / 15ppm 0.1ppm 6811525
Draeger X-am® 2500 - %LEL  Methane
*UL/CSA Approved
2 - 5-100 %VOL only when selected
0 - 100% LEL
0 - 5.0% Vol.
5 - 100% Vol.2
10 / 20% LEL 1% LEL
0.1%Vol.
1.0% Vol.
6812950
Draeger X-am® 2500 - %VOL  Methane 
*MSHA Approved
2 - 5-100 %VOL only when selected
0 - 5.0% Vol.
5 - 100% Vol.2
0.5 / 1.0 % Vol 0.1% Vol.
1.0% Vol.
6813080
Draeger X-am® 2500 Oxygen - O2 0-30% Vol 19.5 / 23.5% Vol 0.1% Vol 8328276
Draeger X-am® 2500 Sulfur Dioxide - SO2 0-50ppm 2 / 4ppm 0.1ppm 6810885
Draeger X-am® 2500 Nitrogen Dioxide - NO2 0-50ppm 2.5 / 5.0ppm 0.1ppm    6810884

 

Draeger X-am® 2500 Specifications

Dimensions (without clip) (W x H x D) 1.85" x 5.12" x 1.73" in / 48 × 130 × 44 mm
Weight 8 - 9 oz
Operating Times > 12 h with alkaline and NiMH,
>13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline
batteries
Charging Times < 4 h
Alarms Visual 360°
Audible Multi-tone > 90 dB at 30 cm
Vibration
Datalogger Retrievable using an infrared interface > 1000 h with 4 gases at a recording interval of 1 value per minute
Protection class IP 67
Air pressure 700 to 1300 mbar 
Air humidity 10 to 95% relative humidity, non-condensing
Temperature - 20 to + 50 °C (-4 to 122°F)
Approvals:
cCSAus, IECEx, ATEX, CE
Class I Div. 1 Group A, B, C, D, A/Ex ia IIC T3/Ga, 
A/Ex d ia IIC T4/T3/Gb, T.-Code T4/T3

 

Draeger X-am® Series Sensor and Warranty Chart
Draeger X-am® Series Sensor and Warranty Chart

Matrix Display -
The Draeger X-am® 2500 has a large, easy to read, liquid-crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2.

High Capacity Battery -
The Dräger X-am 2500 can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours.

Long-lasting, reliable sensor technology -
The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. Further, the Draeger X-am® 2500 is approved for measuring from methane to nonane,one according to IEC/EN 60079-29-1.

Zone Zero Approved -
The Dräger X-am 2500 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.

Diffusion or Pumped -
An optional external pump with a hose up to 98 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

X-dock compatibility -
The X-am 2500 is compatible with Draeger’s X-dock testing and calibration station. X-dock is Draeger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in 8 to 15 seconds with more than 40 % less gas consumption than competitive instruments. The Draeger X-am 2500 is also compatible with the Draeger Bump Test Station.

Ergonomic and robust - even for the toughest conditions -
The Dräger X-am 2500 is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front – even if the instrument is inside a pocket or if the front gas entry is accidentally covered. The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations.

Peak value functionality -