The Draeger X-am® 5600 is the smallest of the 1-6 sensor gas detectors, developed especially for personal monitoring applications where (IR) - Infrared Sensor Technology is needed. This 1- to 6-gas detector reliably measures combustible gases and vapors as well as O2 and harmful concentrations of toxic gases, organic vapors, odorant and amine. Equipped with durable XXS sensor technology, the Draeger X-am 5600 offers maximum safety at extremely low operational costs. Besides hydrocarbons, hydrogen can also be an explosive gas. Because sensors based on infrared technology do not warn against hydrogen explosion dangers, the gas detector X-am 5600 combines two sensor signals (Infrared Ex and electrochemical H2) for reliable hydrogen detection. The X-am 5600 provides the advantages of poison-free technology to be used in areas where, until now, only catalytic Ex sensors have been used. Remember - In an inert or low oxygen environment it is best to use an IR style LEL sensor as a traditional catalytic bead style sensor will not work in a typically below 15% +/- Oxygen environments.
The sensor's resistance, in combination with its long term stability, provides the IR sensors with a lifetime in excess of eight years, which can help reduce your operational costs. The Draeger X-am 5600 is also water and dust resistant, according to IP67 standards. The detector remains fully functional and ready for use, even after being dropped into water. The integrated rubber protection and shockproof sensors provide additional resistance to impact and vibration. Moreover, the Draeger X-am 5600 is resistant to electromagnetic interference.
The Draeger X-am® 5600 gas monitor has an optional external pump with a hose up to 45 m / 147 ft long is available for use in tanks and shafts or when searching for leaks. Switching from diffusion to pump operation can be handled quickly and easily without tools or screws. Which is best of both worlds in gas detection!
Draeger X-am® 5600 Literature
– Measures the following:
(CO) - Carbon Monoxide
(H2S) - Hydrogen Sulfide
(IR-Methane) - Infrared Combustible %LEL / %VOL (%VOL ranges setup in CC Vision software)
(IR-CO2) - Infrared Carbon Dioxide
(Dual IR-Methane / IR-CO2 - Infrared Carbon Dioxide) Infrared Combustible %LEL / %VOL and IR-CO2 - Infrared Carbon Dioxide
(O2) - Oxygen
(SO2) - Sulfur Dioxide
(NO2) - Nitrogen Dioxide
(Ph3) - Phosphine
(HCN) - Hydrogen Cyanide
(NH3) - Ammonia
(CO2) - Carbon Dioxide
(Cl2) - Chlorine
(NO) - Nitric Oxide
(O3) - Ozone
(COCl2) - Phosgene
(OV) - Organic Vapors / Oderants
(CH3SH) - Mercaptans
- Amines
- User Configurable settings with CC-Vision Software by Draeger
- Price breaks for orders in quantities of 10/ 50/ 100 / 200 / 500
Monitor Only Includes:
- Monitor with Selected Sensor
- Comes with cabled Protective Boot ( removeable )
- Diffusion or Pumped Model
- Battery as specified
- Charger Assy not included unless selected with Charging Kit.
- Calibration Certificate
- Manual / Guide
Pump Kit(s) Options:
- Basic Pump Kit comes with: Pump with USB Charger , Wall Plug and Shoulder Strap
- CSE Pump Kit comes with: Pump with USB Cable, Wall Plug, 5m of FKM hose, Float Probe, Shoulder Strap and Pump Kit Case
Calibration Kit Includes / Adds:
- Stainless Steel Regulator(s) depending upon gas selection
- 34/58/116 Liter Cylinders Calibration Gases (specifc gases per selected sensor(s)
- 4 Gas Mix = CO, H2S, LEL -Methane, O2, Bal N2.
- Draeger Calibration / Communication Cradle (without IR-USB)
*(please note we offer other calibration kits depending upon sensor configuration on monitor), please call
Optional Protective Cases / Adds:
- Draeger Custom Foam Cut Case
- Pelican Case - Airtight / Waterproof / Dustproof with Pick n Pluck Foam - Colors may Vary.
Description | Mesuring Range | Measuring Resolution |
Alarm Threshold A1/A2 (standard) | Sensor Order Number & Warranty |
Draeger X-am® 5600 IR -LEL/Combustible Sensors and CO2 Carbon Dioxide Infrared Types | ||||
Draeger X-am® 5600 - IR Ex Methane %Vol Methane only when selected |
0-100% LEL 0-100% Vol. CH4 |
1% LEL 0.1% Vol. CH4 |
10/20% | 6851881 5yr Warranty |
Draeger X-am® 5600 - IR CO2 ES - Carbon Dioxide |
0-5.0% Vol CO2 |
0.01% Vol. |
0.5/1.0% | 6851882 5yr Warranty |
Draeger X_am® 5600 - Dual - IR Ex %LEL Methane and IR CO2 |
0-100% LEL 0-100% Vol. CH4 0-5.0% Vol CO2 |
1% LEL 0.1% Vol. CH4 0.01% Vol. |
10/20% LEL 0.5/1.0 CO2 |
6851880 5yr Warranty |
Draeger X-am® 5600 CO Electrochemical Sensors- | ||||
Draeger X-am® 5600 Carbon Monoxide XXS - CO LC Draeger X-am® 5600 Carbon Monoxide XXS - CO Draeger X-am® 5600 Carbon Monoxide XXS-E - CO Draeger X-am® 5600 Carbon Monoxide XXS - CO HC Draeger X-am® 5600 Carbon Monoxide XXS - CO *H2 compensated Draeger X-am® 5600 Dual Channel (Combo) - Carbon Monoxide / Hydrogen Sulfide XXS - CO/H2S LC Draeger X-am® 5600 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC |
0-2000ppm 0-2000ppm 0-2000ppm 0-10,000ppm 0-2000ppm CO 0-2000ppm - CO 0-100ppm - H2S 0-2000ppm - CO 0-25% vol - O2 |
1ppm 2ppm 2ppm 5ppm 1ppm CO 1ppm CO 0.1ppm H2S 1ppm CO 1% vol O2 |
35/50ppm-CO 35/50ppm-CO 10/15ppm-H2S 35/50ppm-CO 19.5/23.5% Vol-O2 |
6813210 2yr 6810882 5yr 6812212 5yr 6812010 1yr 6811950 2yr 6813280 2yr 6813275 2yr |
Draeger X-am® 5000 H2S Electrochemical Sensors- | ||||
Draeger X-am® 5600 Hydrogen Sulfide XXS - H2S LC Draeger X-am® 5600 Hydrogen Sulfide XXS - H2S Draeger X-am® 5600 Hydrogen Sulfide XXS-E - H2S Draeger X-am® 5600 Hydrogen Sulfide XXS - H2S HC Draeger X-am® 5600 Dual Channel (Combo) - Hydrogen Sulfide / Carbon Monoxide XXS - H2S/CO LC Draeger X-am® 5600 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - H2S/O2 LC |
0-100ppm 0-200ppm 0-200ppm 0-1000ppm 0-100ppm - H2S 0-2000ppm - CO 0-100ppm - H2S 0-25% Vol - O2 |
0.1ppm 1ppm 1ppm 2ppm 0.1ppm H2S 1ppm CO 0.1ppm H2S 1% Vol O2 |
|
6811525 3yr 6810883 5yr 6812213 5yr 6812015 1yr 6813280 2yr 6814137 2yr |
Draeger X-am® 5600 O2 Electrochemical Sensors- | ||||
Draeger X-am® 5600 Oxygen XXS - O2 Draeger X-am® 5600 Oxygen XXS-E - O2 Draeger X-am® 5600 Oxygen XXS - O2 - 100 Draeger X-am® 5600 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC Draeger X-am® 5600 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - O2/H2S LC |
0-25% Vol 0-25% Vol 0-100% Vol 0-25% vol - O2 0-2000ppm - CO 0-25% Vol - O2 0-100ppm - H2S |
0.1% Vol 0.1% Vol 0.5% Vol 1ppm 0.1% Vol 0.1ppm 0.1% Vol |
19.5/23.5% Vol- O2 19.5/23.5% Vol-O2 35/50ppm- CO 19.5/23.5% Vol-O2 10/15ppm-H2S |
6810881 5yr |
Draeger X-am® 5600 Exotic/Toxic Electrochemical Sensors- | ||||
Draeger X-am® 5600 Amines XXS | 0-100ppm | 1ppm | 10/20ppm | 6812545 1yr |
Draeger X-am® 5600 Ammonia XXS - NH3 | 0-300ppm | 1ppm | 25/50ppm |
6810888 1yr |
Draeger X-am® 5600 Carbon Dioxide XXS - CO2 | 0-5% | 0.1% Vol. | 0.5/1.0 | 6810889 1yr |
Draeger X-am® 5600 Chlorine XXS - Cl2 Chlorine Dioxide ClO2 Bromine Br2 Flourine F2 * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-20ppm | 0.1ppm | 0.5/1.0ppm |
6810890 1yr |
Draeger X-am® 5600 Hydrogen Cyanide XXS - HCN Draeger X-am® 5600 Hydrogen Cyanide XXS - HCN PC |
0-50ppm | 1ppm 0.5ppm |
2.5/4.5ppm 5/10ppm |
6810887 2yr 6813165 1yr |
Draeger X-am® 5600 Hydrogen XXS - H2 Draeger X-am® 5600 Hydrogen XXS - H2 HC |
0-2000ppm 0-4% Vol. |
5ppm 0.1% Vol. |
5/10ppm 0.4/0.8% Vol. |
6812370 1yr 6812025 1yr |
Draeger X-am® 5600 Nitrogen Dioxide XXS - NO2 LC Draeger X-am® 5600 Nitrogen Dioxide XXS - NO2 |
0-50ppm | 0.02ppm 0.1ppm |
1.0/2.0ppm 2.5/5.0ppm |
6812600 1yr 6810884 1yr |
Draeger X-am® 5600 Nitrogen Oxide XXS - NO | 0-200ppm | 1ppm | 15/25ppm | 6811545 1yr |
Draeger X-am® 5600 Mercaptan XXS- CH4S | 0-40ppm | 1ppm | 10/20ppm | 6812535 1yr |
Draeger X-am® 5600 Organic Vapor XXS-OV EthyleneOxide Propylene Oxide Ethene Propene Vinyl Chloride Methanol Butadiene Formaldehyde Isopropanol Tetrahydrofuan 1-Chloro-2,3 Epoxypropane Styrene Methyl Methacrylate * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm 0-200ppm 0-100ppm 0-100ppm 0-300ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm |
0.5ppm | 6811530 1yr | |
Draeger X-am® 5600 Organic Vapor-A XXS- OV-A Ehtylene Oxide Acrylonitrile Isobutylene Vinyl Acetate Ethanol Acetaldehyde Diethyl Ether Acetylene * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-100ppm 0-300ppm 0-100ppm 0-300ppm 0-200ppm 0-200ppm 0-100ppm |
1ppm | 6811535 1yr | |
Draeger X-am® 5600 Ozone XXS- O3 | 0-10ppm | 1ppm | 0.1/0.2ppm | 6811540 1yr |
Draeger X-am® 5600 Phosegene XXS- COCl2 | 0-10ppm | 0.01ppm | 0.1/0.2ppm | 6812005 1yr |
Draeger X-am® 5600 Phosphine XXS- PH3 Draeger X-am® 5600 Phosphine XXS- PH3 HC |
0-20ppm 0-1000ppm |
0.1ppm 1ppm |
0.1/0.2 50-100ppm |
6810866 1yr 6812020 1yr |
Draeger X-am® 5600 Sulfur Dioxide XXS- S02 | 0-50ppm | 0.1ppm | 2/4ppm | 6810885 1yr |
Draeger X-am® 5600 Specifications-
Dimensions (W x H x D) | 1.89" x 5.12" x 1.7" (48 x 130 x 44 mm) |
Weight | 220-250g |
Operating Times | > 12 hours with Alkaline and NiMH > 13 hours with NiMH HC; without Ex Sensor typ > 250 hours with Alkaline Battery > 40 hours when using the Save Energy Mode |
Charging Times | < 4 h |
Pump Operation | Max. hose length 147.6 feet (45 m) |
Alarms | Visual = 360° Audible = Multi-tone > 90 dB at 30 cm Vibration |
Datalogger | Can be read out via Infrared > 1,000 hours with 5 gases and arecording interval of 1 value per minute |
Protection class | IP 67 |
Air pressure | 700 to 1300 mbar |
Air humidity | 10 to 95 % r.h. |
Temperature | -4 to 122 °F (for max. 15 minutes) |
Warranty | 3 years for the device and CO, H2S, LEL, O2 sensors. 5 years for the E Series Sensors as listed 5 years on the IR Sensors 1 year exotic sensors 1 year for the power supply Sensors: see DraegerSensor® & Portable Instruments Handbook (below) |
Approvals: IECEx, ATEX cCSAus |
I M1 Ex da ia I MaII 1G Ex da ia IIC T4/T3 Ga Class I Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3A/Ex da ia IIC T4/T3 /Ga |
Draeger X-am® Series Sensor and Warranty Chart-
Draeger X-am® Series Sensor and Warranty Chart
1-6 Gases -
The Draeger X-am® 5600 has the ability to read up to 6 gases at once.
Durable infrared technology -
Thanks to the high stability and a resistance to contamination, Dräger infrared sensors can generally be used for up to eight years. This advanced technology reduces the cost of ownership considerably because less replacement sensors are needed. In addition, a sensor calibration is only necessary every 12 months which reduces maintenance costs.
Single or dual sensor—accurate measurement results -
The infrared sensor IR Ex allows the measurement of explosive, combustible hydrocarbons in the range of the lower explosive limit. The infrared sensor IR CO2, with a measurement resolution of 0.01 Vol.-%, provides safe and exact measurements as well as a warning against toxic concentrations of carbon dioxide in the ambient air. For those applications where the reliable measurement of explosive substances and CO2 is specifically needed, the advantages of both can be achieved by a dual sensor (Dual IR CO2/Ex).
Also in combination with Hydrogen -
Besides hydrocarbons, hydrogen can also be an explosive gas. Because sensors based on infrared technology do not warn against hydrogen explosion dangers, the gas detector X-am 5600 combines two sensor signals (Infrared Ex and electrochemical H2) for reliable hydrogen detection. The X-am 5600 provides the advantages of poison-free technology to be used in areas where, until now, only catalytic Ex sensors have been used.
X-Zone Compatible -
The Draeger X-am® 5600 is designed to work with the Draeger X-Zone system for Area Monitoring.
Matrix Display -
The Draeger X-am® 5600 has a easy to read, liquid-crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2.
High Capacity Battery -
The Draeger X-am 5600 can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours.
Long-lasting, reliable sensor technology -
The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. Further, the Draeger X-am® 5600 is approved for measuring from methane to nonane,one according to IEC/EN 60079-29-1.
Zone Zero Approved -
The Dräger X-am 5600 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.
Diffusion or Pumped -
An optional external pump with a hose up to 98 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.
X-dock compatibility -
The X-am 5600 is compatible with Draeger’s X-dock testing and calibration station. X-dock is Draeger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in 8 to 15 seconds with more than 40 % less gas consumption than competitive instruments. The Draeger X-am 2500 is also compatible with the Draeger Bump Test Station.
Ergonomic and robust - even for the toughest conditions -
The Draeger X-am 5600 is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front – even if the instrument is inside a pocket or if the front gas entry is accidentally covered. The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations.
Peak value functionality -
The X-am 5600 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the O2 sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.