AreaRAE Plus - Rental

AreaRAE Plus - Rental

MultiRAE Lite - Rental

MultiRAE Lite - Rental

Draeger X-am® 8000 Multi-Gas + VOC Monitors - Rental

SKU
X-am 8000-Rental

Draeger X-am® 8000 -

The Draeger X-am® 8000​ was especially designed for clearance measurements and personnel monitoring applications. The 1 to 7 gas detector reliably detects flammable gases such as %LEL (catalytic bead) or IR %LEL / %VOL sensors and vapors as well as O2, CO, H2S, NO, PH3, NO2, HCN, NH3, CO2, Cl2, Clo2, H2, OV, Amine, Oderant, COCl2, Ozone, VOC's (ppm/ppb ranges), and SO2. The innovative signaling design and extensive range of accessories ensure optimum safety and easy handling. Specifically designed to use with a pump, the pump adapter can be removed and the X-am 8000 can be used as a diffusion instrument. Similar in design as the four-gas sensor X-am 3500 series, but as a seven-gas sensor option.

The X-am® 8000 by Draeger was specifically designed for use with an internal pump optimized for clearance measurements. The pump is very powerful and can handle a draw up to 147 feet. The included pump adapter makes it very easy and efficient at switching from a pumped mode to a diffusion mode by simply unscrewing and removing the pump adapter module. This saves enerygy, ensures the pump is only used when needed, reduces wear and tear on the pump and extends the pump life. On startup, the X-am® 8000 has a built in protocol the operator to stall the pump. This is another excellent built in safety feature to ensure the instrument is operating correctly before use.

Draeger X-am® 8000 Literature 

Benefits-

The X-am 8000 is a specialist for high and low hydrocarbon concentrations. You can fit the X-am 8000 one of two high-performance PID Sensors. Either a PID HC for 0-2000ppm or a PID LC for 0-10ppm and range below 1ppm. 

You can also purchase seperately a pre-tube assy for Benzene specific measurements. The meter has a built in function for using the Draeger Benzene tubes for Benzene measurement.

Inductive Charging protects against wear and tear. You can also connect the charging cradles to one another to maximize your table/desk space.

X-DOCK capable. The X-am 8000 series is ready to use the Draeger X-Dock series auto-calibration and bump test station. The X-Dock can be easily put on a network and with the help of the X-Dock Management software sold seperately.

RFID Management. With the optional built in RFID badge, you can easily identify your Draeger X-am 8000 devices in the field for an excellent administration control.

%LEL / %Vol Methane Detection. When measuring for high Methane concentrations you can configure automatic measurement range switching option. If a reading goes higher than say 100% LEL, the display swithes to the range of 0-100% Vol.

Clearance Measurement. The Draeger X-am 8000 has a built in confined space assistant where when activated it calculates the time it takes for the measurement to flow from the end of the probe (FKM Hose) to the unit. Based on parameters such measuring gases, temperature limits, and indicated hose length. 

The Draeger X-am 8000 unit also has a clear color code system.
- Red light = gas alarm
- Yellow light = device-related alarm (low battery)
- Green light = device is ready for use

The green glow D-Light allows you to see from a distance whether the unit has been properly tested and ready for use.

Draeger X-am® 8000 Sensor Specifications-

Specifications
Description Mesuring Range Measuring Resolution
Alarm Threshold A1/A2 (standard) Sensor Order Number & Warranty
Draeger X-am® 8000 PID Sensors-        
Draeger X-am® 8000 (ppm) PID HC - Isobutene
Draeger X-am® 8000 (ppm) PID HC - Benzene 
0-2000ppm
0-1000ppm 
  0.1ppm  50/100ppm 6813475
1yr Warranty
Draeger X-am® 8000 (ppb) PID LC - Isobutene
Draeger X-am® 8000 (ppb) PID LC - Benzene
0.05-10ppm
0-5ppm
10ppb 5/10ppm  6813500
1yr Warranty
Draeger X-am® 8000 LEL/Combustible Sensors-
Catalytic Bead and Infrared Types
       
Draeger X-am® 8000 - Cat-Ex 125 PR - Methane
%Vol Methane only when selected
Special Calibrations allowed
0-100% LEL
0-5.0% Vol CH4
5-100% Vol. CH4
1% LEL
0.1% Vol.
1.0% Vol.
10/20%  6812950
3yr Warranty
Draeger X-am® 8000 - Cat-Ex 125 PR - Methane
%Vol Methane only when selected
Special Calibrations allowed / MSHA Approved
0-100% LEL
0-5.0% Vol CH4
5-100% Vol. CH4
1% LEL
0.1% Vol.
1.0% Vol.
0.5/1.0%  6813080
2yr Warranty
Draeger X-am® 8000 - (IR) Infrared Ex ES  
%Vol Methane only when selected
Vol = -Methane, Ethane, n-Butane
Special Calibrations allowed
 0-100% LEL
0-100% Vol
 1% LEL
0.1%Vol. CH4
10/20%   6851881
5yr Warranty 
Draeger X-am® 8000 IR Infrared Sensors-
CO2 & Combo CO2/LEL Types
       
Draeger X-am® 8000 - (IR) Infrared CO2 ES

0-9,900ppm
0-5.0% Vol CO2

50ppm CO2 0.02% Vol. CO2 

0.5/1.0%  6851882
5yr Warranty
Draeger X-am® 8000 - Dual IR Ex/CO2 ES - Methane
%Vol Methane only when selected
Vol = -Methane, Ethane, n-Butane
Special Calibrations allowed
0-100% LEL
0-100% Vol
0-5% Vol CO2
1% LEL
0.1%Vol. CH4 
0.1%Vol. CO2 or 50ppm CO2
 10/20%
0.5/1.0%
 6851880
5yr Warranty
Draeger X-am® 8000 - Dual IR Ex/CO2 HC  Methane
%Vol Methane only when selected
Vol = -Methane, Ethane, n-Butane
Special Calibrations allowed
*No PID installed with this sensor.

0-100% LEL
0-100% Vol
0-100% Vol CO2
 1% LEL
0.1%Vol.CH4  
0.1%Vol.CO2 
  10/20%
0.5/1.0%
6800276
5yr Warranty 
Draeger X-am® 8000 CO Electrochemical Sensors-        
Draeger X-am® 8000 Carbon Monoxide XXS - CO LC
Draeger X-am® 8000 Carbon Monoxide XXS - CO
Draeger X-am® 8000 Carbon Monoxide XXS-E - CO
Draeger X-am® 8000 Carbon Monoxide XXS - CO HC
Draeger X-am® 8000 Carbon Monoxide XXS - CO *H2 compensated

Draeger X-am® 8000 Dual Channel (Combo) -
Carbon Monoxide / Hydrogen Sulfide XXS - CO/H2S LC

Draeger X-am® 8000 Dual Channel (Combo) -
Carbon Monoxide / Oxygen XXS - CO/O2 LC

Draeger X-am® 8000 Dual Channel (Combo) -
Carbon Monoxide / Hydrogen Cyanide XXS - CO/HCN
0-2000ppm
0-2000ppm
0-2000ppm
0-10,000ppm
0-2000ppm CO


0-2000ppm - CO
0-100ppm - H2S

0-2000ppm - CO
0-25% vol - O2 

0-2000ppm - CO
0-50ppm - HCN
1ppm
2ppm
2ppm
5ppm
1ppm CO


1ppm CO
0.1ppm H2S

1ppm CO
1% vol O2

1ppm CO
0.1ppm HCN


35/50ppm-CO




35/50ppm-CO
10/15ppm-H2S

35/50ppm-CO
19.5/23.5% Vol-O2

35/50ppm-CO
2.5/4.5ppm-HCN
6813210 2yr
6810882 5yr
6812212 5yr
6812010 1yr
6811950 2yr


6813280 2yr


6813275 2yr


6800040 1yr

Draeger X-am® 8000 H2S Electrochemical Sensors-        
Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S LC
Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S
Draeger X-am® 8000 Hydrogen Sulfide XXS-E - H2S
Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S HC

Draeger X-am® 8000 Dual Channel (Combo) - Hydrogen Sulfide / Carbon Monoxide XXS - H2S/CO LC

Draeger X-am® 8000 8000 Dual Channel (Combo) -  Hydrogen Sulfide / Oxygen XXS -  H2S/O2 LC
0-100ppm
0-200ppm
0-200ppm
0-1000ppm 

0-100ppm - H2
0-2000ppm - CO

0-100ppm - H2S
0-25% Vol - O2
0.1ppm
1ppm
1ppm
 2ppm

0.1ppm H2S
1ppm CO

0.1ppm H2S
1% Vol O2


10/15ppm-H2S



10/15ppm-H2S
35/50ppm-CO

10/15ppm-H2S
19.5/23.5% Vol-O2

6811525 3yr
6810883 5yr
6812213 5yr
6812015 1yr


6813280 2yr


6814137 2yr

Draeger X-am® 8000 O2 Electrochemical Sensors-        
Draeger X-am® 8000 Oxygen XXS - O2
Draeger X-am® 8000 Oxygen XXS-E - O2
Draeger X-am® 8000 Oxygen XXS - O2 - 100

Draeger X-am® 8000 Dual Channel (Combo) -
Carbon Monoxide / Oxygen XXS - CO/O2 LC

Draeger X-am® 8000 8000 Dual Channel (Combo) -  Hydrogen Sulfide / Oxygen XXS -  O2/H2S LC
0-25% Vol
0-25% Vol

0-100% Vol

0-25% vol - O2
0-2000ppm - CO


0-25% Vol - O2
 0-100ppm - H2S
0.1% Vol
0.1% Vol
0.5% Vol

1ppm 
0.1% Vol

0.1ppm 
0.1% Vol

19.5/23.5% Vol- O2


19.5/23.5% Vol-O2
35/50ppm- CO

19.5/23.5% Vol-O2
10/15ppm-H2S

6810881 5yr
6812213 5yr
6812385 1yr


6813275 2yr


6814137 2yr

Draeger X-am® 8000 Exotic/Toxic Electrochemical Sensors-         
Draeger X-am® 8000 Amines XXS  0-100ppm   1ppm 10/20ppm  6812545 1yr
Draeger X-am® 8000 Ammonia XXS - NH3 0-300ppm  1ppm 
25/50ppm

6810888 1yr
Draeger X-am® 8000 Carbon Dioxide XXS - CO2 0-5% 0.1% Vol. 0.5/1.0 6810889 1yr
Draeger X-am® 8000 Chlorine XXS - Cl2
    Chlorine Dioxide ClO2
    Bromine Br2
    Flourine F2
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook
0-20ppm  0.1ppm  0.5/1.0ppm
6810890 1yr
Draeger X-am® 8000 Hydrogen Cyanide XXS - HCN
Draeger X-am® 8000 Hydrogen Cyanide XXS - HCN PC
0-50ppm 1ppm
0.5ppm
2.5/4.5ppm
5/10ppm
6810887 2yr
6813165 1yr
Draeger X-am® 8000 Hydrogen XXS - H2 
Draeger X-am® 8000 Hydrogen XXS - H2 HC
0-2000ppm
0-4% Vol. 
 5ppm
0.1% Vol.
 5/10ppm
0.4/0.8% Vol.
6812370 1yr
6812025 1yr 
Draeger X-am® 8000 Nitrogen Dioxide XXS - NO2 LC
Draeger X-am® 8000 Nitrogen Dioxide XXS - NO2
0-50ppm 0.02ppm
0.1ppm
1.0/2.0ppm
2.5/5.0ppm
6812600 1yr
6810884 1yr
Draeger X-am® 8000 Nitrogen Oxide XXS - NO  0-200ppm 1ppm   15/25ppm 6811545 1yr 
Draeger X-am® 8000 Mercaptan XXS- CH4S 0-40ppm 1ppm 10/20ppm 6812535 1yr
Draeger X-am® 8000 Organic Vapor XXS-OV
    EthyleneOxide
    Propylene Oxide
    Ethene
    Propene
    Vinyl Chloride
    Methanol
    Butadiene
    Formaldehyde
    Isopropanol
    Tetrahydrofuan
    1-Chloro-2,3 Epoxypropane
    Styrene
    Methyl Methacrylate
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook

0-200ppm
0-200ppm
0-100ppm
0-100ppm
0-100ppm
0-200ppm
0-100ppm
0-100ppm
0-300ppm
0-200ppm
0-100ppm
0-100ppm
0-100ppm


0.5ppm   6811530 1yr
Draeger X-am® 8000 Organic Vapor-A XXS- OV-A
    Ehtylene Oxide
    Acrylonitrile
    Isobutylene
    Vinyl Acetate
    Ethanol
    Acetaldehyde
    Diethyl Ether
    Acetylene
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook

0-200ppm
0-100ppm
0-300ppm
0-100ppm
0-300ppm
0-200ppm
0-200ppm
0-100ppm


1ppm   6811535 1yr
Draeger X-am® 8000 Ozone XXS- O3 0-10ppm 1ppm 0.1/0.2ppm 6811540 1yr
Draeger X-am® 8000 Phosegene XXS- COCl2 0-10ppm 0.01ppm 0.1/0.2ppm 6812005 1yr
Draeger X-am® 8000 Phosphine XXS- PH3
Draeger X-am® 8000 Phosphine XXS- PHHC
0-20ppm
0-1000ppm
0.1ppm
1ppm
0.1/0.2
50-100ppm
6810866 1yr
6812020 1yr
Draeger X-am® 8000 Sulfur Dioxide XXS- S02 0-50ppm 0.1ppm 2/4ppm 6810885 1yr

 

Draeger X-am® 8000 Specifications-

Dimensions (without clip) (W x H x D) 7.0" x 3.0" x 1.7" (179 x 77 x 42 mm)
Weight Approx. 495 g (17.5 ounces), depending on sensor configuration, without strap, without pump
Approx. 550 g (19.4 ounces), depending on sensor configuration, without strap, with pump
Operating Times With CatEx and 3 EC sensors Typically 24 hours
With IR and 3 EC Sensors Typically 22 hours
With 3 EC-sensors Typically 120 hours
With IR, PID and 3 EC Sensors Typically 16 Hours
With PID Only Typically 42 hours
Charging Times Typically 4 hours after use during a shift of max. 10 hours
Pump Operation Max. hose length 147.6 feet (45 m)
Alarms Visual = 3 LED 'red' (gas alarms), 3 LED 'yellow' (device alarms)
Acoustic = Multi-tone, typically 100 dB(A) at 30 cm
Vibration
Datalogger 12 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 4 channels: approx. 300 hours
Protection class IP 67
Air pressure 700 to 1300 mbar 
Air humidity 10 to 90% (short-term up to 95%) r.h.
Temperature -4°F to 122°F (-20 °C to +50 °C)
Warranty 3 years for the device and CO, H2S, LEL, O2 sensors.
1 year exotic sensors
1 year for the power supply
Sensors: see DraegerSensor® & Portable Instruments Handbook (below) 
Approvals:
IECEx, ATEX


cCSAus

I M1, II 1G
Ex da ia I Ma, Ex da ia IIC T4 Ga / Metrological approval pending

Class I, Zone 0. ( intrinsically safe )
Class II, Div 1, Gr. E, F, G T4
C22.2 No. 152, ANSI-ISA 12.13.01:2000

 

Draeger X-am® Series Sensor and Warranty Chart-
Draeger X-am® Series Sensor and Warranty Chart

Standard Monitor Includes:
- X-am 8000 unit with specified sensors
- Rechargeable Battery
- Internal Pump and Pump Adapter
- Shoulder Strap
- Inductive Charger and Wall Plug

Monitor with Optional Calibration Kit B adds:
- Standard Accessories
- Calibration Adapter x 1
-
1 each Stainless Regulator
-
1 each 44 Liter of Quad Mix (C0,H2S,LEL and O2) Gas for X-am 8000 

Monitor with Optional Calibration Kit B adds:

- Standard Accessories 
- Calibration Adapter x 1
- 1 each Stainless Regulator
- 1 each 44 Liter of Quad Mix (C0,H2S,LEL and O2) Gas for X-am 8000 
- 1 each 44 Liter of 100 ppm Isobutylene Gas for VOC Sensor

*please note we offer other calibration kits depending upon sensor configuration on monitor - Please call for a custom quote for calibration equipment needed for  your selection of sensors. We are an authorized DOT / IATA shipper for calibration gases.