* Additional regulator needed if fresh air cylinder is desired.
* See our Calibration Gases for Draeger Specific cylinders.
* FKM Tubing included with each regulator purchased.
* Teflon Tubing included for Chlorine gas purchased.
* Call if you would like pre-configured before shipping.
Draeger X-dock® 6600-
The Draeger X-dock® 6600 is designed for Automatic bump testing, calibrations, reduced test gas consumption, short testing times, and comprehensive documentation for Draeger Gas Detectors.
The 6600 X-dock® Master Controller by Draeger was specifically designed for use when you have an application for calibrating / testing a Draeger gas monitor that requires more than 3 calibration gas mixtures and/or can handle up to 6 different calibration gas cylinders. Up to 10 each PAC, 1/2/5 Cradle modules or 5 each X-am 3500/8000 modules can be connected to the X-dock®, allowing you to test gas detection instruments simultaneously or independently of each other. The automatic bump test also saves time, because the test only takes 8 to 15 seconds. All Draeger test gas cylinders are already stored in the database—just enter the part number to automatically fill the fields required for the gas configuration, eliminating the need for manual data entry with private label gases. Administration control for what takes place during testing such as configuration of: Date/Time, pulling the Data-logging and/or clearing Data-logging on the unit(s), Check and verify the configuration (5100, 2500, 5000 series), Alarm checks (visual,audible,settings for low and high), auto-zero, calibration / bump testing time, purging, and auto pdf reporting.
The X-dock® engineered advantage all starts with intuitive touchscreen operation at the master controller station
where up to three test routines can be configured. Testing is as simple as inserting your Dräger gas detection
instrument and closing the lid. The X-dock® immediately detects all sensor combinations and automatically
tests and adjusts when all of the required test gases are connected. All generated data is documented in the
database.
Draeger 6600 X-dock Gas Connections |
6 different test gases +one fresh air inlet + one waste gas outlet | * Fresh Air inlet may require additional Pressure Regulator |
X-dock Controller Dimensions | Approx. 4.7 x 5.11 x 9.84 in | |
X-dock Controller Weight |
Approx. 3.3 lbs | |
X-dock PAC/X-am 1/25 Module- Dimensions | Approx. 3.54 x 5.71 x 9.84 in | *Max 10ea Pac or 1/2/5 Cradles |
X-dock X-am 3500 / 8000 Module Dimensions |
Approx. 4.80 x 5.71 x 9.84 in | *Max 5ea 3500 / 8000 Cradles |
Draeger Specific Pressure Regulator(s) * One regulator per gas used. |
Standard Non Reactive Gases Non Corrosive Gases |
Stainless Steel Reactive Gases Corrosive Gases |
Internal Memory Size | 2GB |
Features:
‒ Touchscreen operation at the master controller station
‒ Up to three configurable test routines
‒ Automatic permeability tests
‒ Automatic tests of all alarm elements (acoustic, visual and vibration alarms)
‒ Optional charging function for X-am®
‒ Easy to replace seal cartridge
‒ 12V operation (e.g., in vehicles) available
‒ Can be subsequently expanded with up to max. 10 modules (X-dock® 6300/6600)
‒ Sensor performance testing
3 USB Ports:
- Pulling Calibration/Bump Test completion reports
- Adding in to a Network / Server environment (add in X-Dock Management Software for additional cost)
- Attaching a printer for quick paper copy reports
- Easy to use Firmware updates
1 Ethernet Port:
- Access for the XM X-dock Manager Software (additional charge)
- Server, Multiple location, Data-reporting, configuration changes or updating.
Cradles available:
Pac Series Cradle, 1/2/5 Cradle, 3500/8000 Cradle.
Power Supply Unit (PSU) for Controller: -Two optional PSU's with base station:
1.25amp for maximum of 3 Cradles
6.25amp for maximum of 10 Cradles total.
*If choosing the 3500/8000 series cradle, max is 5 cradles.