* Discontinued. Parts still available. *
* Cannot combine Sulfur Dioxide SO2 and Ammonia NH3 sensors in the same unit. *
* Hydrogen Cyanide HCN sensor can only be ordered in the Tox 1 location when the Duo-Tox (CO/H2S) sensor is ordered in the Tox 2 location. All other configurations, HCN must be ordered in the Tox 2 location. *
(Discontinued - Parts Still Available)
BW Honeywell - Gas Alert Micro 5 Diffusion (no pump) with PID Multi-Gas Detector.
Providing protection from up to five potential atmospheric hazards including oxygen, combustible and toxic gases, GasAlertMicro 5 is unparalleled in its versatility, capability and overall value. BW Technologies by Honeywell's newest addition to its water-resistant line of portable gas detectors has transformed the market with its matchless array of features.
Continuously monitoring and displaying concentrations of up to five gases, the compact and lightweight GasAlertMicro 5 was designed and engineered with an extensive host of applications in mind.
Gas Alert Micro 5 Data Sheet
Sensor | Range | Resolution |
PID - VOC | 0-1000ppm | 1.0ppm |
Ammonia - NH3 | 0-100ppm | 1ppm |
Carbon Monoxide - CO | 0-999ppm | 1ppm |
CO/H2S Duo Tox - CO,H2S | CO: 0-500ppm H2S: 0-500ppm |
1ppm |
Chlorine - Cl2 | 0-50.0ppm | 0.1ppm |
Chlorine Dioxide - ClO2 | 0-1.00ppm | 0.01ppm |
Combustible - LEL (methane) | 0-100% LEL | 1% LEL |
Hydrogen Cyanide - HCN | 0-30.0ppm | 0.1ppm |
Hydrogen Sulfide - H2S | 0-500ppm | 1ppm |
Nitrogen Dioxide - NO2 | 0-99.9ppm | 0.1ppm |
Oxygen - O2 | 0-30%vol | 0.1%vol |
Ozone - O3 | 0-100ppm | 0.01ppm |
Phosphine - PH3 | 0-5.0ppm | 0.1ppm |
Sulfur Dioxide - SO2 | 0-150ppm | 1ppm |
Self-Tests:
Optional Kits:
-Confined Space Kit Includes - Manual aspirator kit, sampling probe with holster, five spare auxillary filters and three spare quick connect fittings, 10ft sampling hose, carry holster, calibration cap and 1.0 LPM regulator.
-Confined Space Kit (CSK) with Calibration Kit Includes - Manual aspirator kit, sampling probe with holster, five spare auxillary filters and three spare quick connect fittings, 10ft sampling hose, carry holster, calibration cap, 1.0 LPM regulator and one 34Liter Cylinder of Quad Mix (4Gas - CO, H2S, LEL, O2) and one 34L Isobutylene Mix (PID). (For other gas mixtures please call.)
Features: