The Draeger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as O2 and harmful concentrations of toxic gases, organic vapors, odorant and amine. Equipped with durable XXS sensor technology, the Draeger X-am 5000 offers maximum safety at extremely low operational costs. The sensor's resistance, in combination with its long term stability, provides the sensor with a lifetime in excess of four years, which can help reduce your operational costs. The Draeger X-am 5000 is also water and dust resistant, according to IP67 standards. The detector remains fully functional and ready for use, even after being dropped into water. The integrated rubber protection and shockproof sensors provide additional resistance to impact and vibration. Moreover, the Draeger X-am 5000 is resistant to electromagnetic interference.

The Draeger X-am® 5000 gas monitor has an optional external pump with a hose up to 45 m / 147 ft long is available for use in tanks and shafts or when searching for leaks. Switching from diffusion to pump operation can be handled quickly and easily without tools or screws. Whoch is best of both worlds in gas detection!

Draeger X-am® 5000 Literature

– Measures the following:
      (CO) - Carbon Monoxide
      (H2S) - Hydrogen Sulfide
      (Methane) - UL/CSA Combustible %LEL / %VOL (%VOL ranges setup in CC Vision software)
      (Methane) - MSHA Combustible %VOL (%VOL ranges setup in CC Vision software)
      (O2) - Oxygen
      (SO2) - Sulfur Dioxide
      (NO2) - Nitrogen Dioxide
      (Ph3) - Phosphine
      (HCN) - Hydrogen Cyanide
      (NH3) - Ammonia
      (CO2) - Carbon Dioxide
      (Cl2) - Chlorine
      (NO) - Nitric Oxide
      (O3) - Ozone
      (COCl2) - Phosgene
      (OV) - Organic Vapors / Oderants
      (CH3SH) - Mercaptans
       - Amines
     

- User Configurable settings with CC-Vision Software by Draeger

- Price breaks for orders in quantities of 10/ 50/ 100 / 200 / 500

 

Monitor Only Includes:

- Monitor with Selected Sensor

- Diffusion or Pumped Model

- Battery as specified

- Charger Assy not included unless selected with Charging Kit.

- Calibration Certificate

- Manual / Guide

 

Pump Kit(s) Options:

- Basic Pump Kit comes with: Pump with USB Charger , Wall Plug and Shoulder Strap

- CSE Pump Kit comes with: Pump with USB Cable, Wall Plug, 5m of FKM hose, Float Probe, Shoulder Strap and Pump Kit Case

 

Calibration Kit Includes / Adds:

- Stainless Steel Regulator(s) depending upon gas selection

- 34/58/116 Liter Cylinders Calibration Gases (specifc gases per selected sensor(s)

- 4 Gas Mix = CO, H2S, LEL -Methane, O2, Bal N2.

- Draeger Calibration / Communication Cradle (without IR-USB)

 *(please note we offer other calibration kits depending upon sensor configuration on monitor), please call

 

Optional Protective Cases / Adds:

- Draeger Custom Foam Cut Case

- Pelican Case - Airtight / Waterproof / Dustproof with Pick n Pluck Foam - Colors may Vary.

Draeger X-am® 5000 Sensor Specifications-

Specifications
Description Mesuring Range Measuring Resolution
Alarm Threshold A1/A2 (standard) Sensor Order Number & Warranty
Draeger X-am® 5000 LEL/Combustible Sensors-
Catalytic Bead Types
       
Draeger X-am® 5000 - Cat-Ex 125 PR - Methane
%Vol Methane only when selected
Special Calibrations allowed
0-100% LEL
0-5.0% Vol CH4
5-100% Vol. CH4
1% LEL
0.1% Vol.
1.0% Vol.
10/20%  6812950
3yr Warranty
Draeger X-am® 5000 - Cat-Ex 125 PR - Methane
%Vol Methane only when selected
Special Calibrations allowed / MSHA Approved
0-100% LEL
0-5.0% Vol CH4
5-100% Vol. CH4
1% LEL
0.1% Vol.
1.0% Vol.
0.5/1.0%  6813080
2yr Warranty
Draeger X-am® 5000 CO Electrochemical Sensors-        
Draeger X-am® 5000 Carbon Monoxide XXS - CO LC
Draeger X-am® 5000 Carbon Monoxide XXS - CO
Draeger X-am® 5000 Carbon Monoxide XXS-E - CO
Draeger X-am® 5000 Carbon Monoxide XXS - CO HC
Draeger X-am® 5000 Carbon Monoxide XXS - CO *H2 compensated

Draeger X-am® 5000 Dual Channel (Combo) -
Carbon Monoxide / Hydrogen Sulfide XXS - CO/H2S LC

Draeger X-am® 5000 Dual Channel (Combo) -
Carbon Monoxide / Oxygen XXS - CO/O2 LC
0-2000ppm
0-2000ppm
0-2000ppm
0-10,000ppm
0-2000ppm CO


0-2000ppm - CO
0-100ppm - H2S

0-2000ppm - CO
0-25% vol - O2 
1ppm
2ppm
2ppm
5ppm
1ppm CO


1ppm CO
0.1ppm H2S

1ppm CO
1% vol O2


35/50ppm-CO




35/50ppm-CO
10/15ppm-H2S

35/50ppm-CO
19.5/23.5% Vol-O2
6813210 2yr
6810882 5yr
6812212 5yr
6812010 1yr
6811950 2yr



6813280 2yr


6813275 2yr
Draeger X-am® 5000 H2S Electrochemical Sensors-        
Draeger X-am® 5000 Hydrogen Sulfide XXS - H2S LC
Draeger X-am® 5000 Hydrogen Sulfide XXS - H2S
Draeger X-am® 5000 Hydrogen Sulfide XXS-E - H2S
Draeger X-am® 5000 Hydrogen Sulfide XXS - H2S HC

Draeger X-am® 5000 Dual Channel (Combo) - Hydrogen Sulfide / Carbon Monoxide XXS - H2S/CO LC

Draeger X-am® 5000 Dual Channel (Combo) -  Hydrogen Sulfide / Oxygen XXS -  H2S/O2 LC
0-100ppm
0-200ppm
0-200ppm
0-1000ppm 


0-100ppm - H2
0-2000ppm - CO


0-100ppm - H2S
0-25% Vol - O2
0.1ppm
1ppm
1ppm
 2ppm


0.1ppm H2S
1ppm CO


0.1ppm H2S
1% Vol O2



10/15ppm-H2S



10/15ppm-H2S
35/50ppm-CO


10/15ppm-H2S
19.5/23.5% Vol-O2

6811525 3yr
6810883 5yr
6812213 5yr
6812015 1yr



6813280 2yr


6814137 2yr

Draeger X-am® 5000 O2 Electrochemical Sensors-        
Draeger X-am® 5000 Oxygen XXS - O2
Draeger X-am® 5000 Oxygen XXS-E - O2
Draeger X-am® 5000 Oxygen XXS - O2 - 100


Draeger X-am® 5000 Dual Channel (Combo) -
Carbon Monoxide / Oxygen XXS - CO/O2 LC


Draeger X-am® 5000 Dual Channel (Combo) -  Hydrogen Sulfide / Oxygen XXS -  O2/H2S LC
0-25% Vol
0-25% Vol

0-100% Vol



0-25% vol - O2
0-2000ppm - CO


0-25% Vol - O2
 0-100ppm - H2S
0.1% Vol
0.1% Vol
0.5% Vol



1ppm 
0.1% Vol

0.1ppm 
0.1% Vol

19.5/23.5% Vol- O2



19.5/23.5% Vol-O2
35/50ppm- CO

19.5/23.5% Vol-O2
10/15ppm-H2S

6810881 5yr
6812213 5yr
6812385 1yr




6813275 2yr


6814137 2yr

Draeger X-am® 5000 Exotic/Toxic Electrochemical Sensors-         
Draeger X-am® 5000 Amines XXS  0-100ppm   1ppm 10/20ppm  6812545 1yr
Draeger X-am® 5000 Ammonia XXS - NH3 0-300ppm  1ppm 
25/50ppm

6810888 1yr
Draeger X-am® 5000 Carbon Dioxide XXS - CO2 0-5% 0.1% Vol. 0.5/1.0 6810889 1yr
Draeger X-am® 5000 Chlorine XXS - Cl2
    Chlorine Dioxide ClO2
    Bromine Br2
    Flourine F2
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook
0-20ppm  0.1ppm  0.5/1.0ppm
6810890 1yr
Draeger X-am® 5000 Hydrogen Cyanide XXS - HCN
Draeger X-am® 5000 Hydrogen Cyanide XXS - HCN PC
0-50ppm 1ppm
0.5ppm
2.5/4.5ppm
5/10ppm
6810887 2yr
6813165 1yr
Draeger X-am® 5000 Hydrogen XXS - H2 
Draeger X-am® 5000 Hydrogen XXS - H2 HC
0-2000ppm
0-4% Vol. 
 5ppm
0.1% Vol.
 5/10ppm
0.4/0.8% Vol.
6812370 1yr
6812025 1yr 
Draeger X-am® 5000 Nitrogen Dioxide XXS - NO2 LC
Draeger X-am® 5000 Nitrogen Dioxide XXS - NO2
0-50ppm 0.02ppm
0.1ppm
1.0/2.0ppm
2.5/5.0ppm
6812600 1yr
6810884 1yr
Draeger X-am® 5000 Nitrogen Oxide XXS - NO  0-200ppm 1ppm   15/25ppm 6811545 1yr 
Draeger X-am® 5000 Mercaptan XXS- CH4S 0-40ppm 1ppm 10/20ppm 6812535 1yr
Draeger X-am® 5000 Organic Vapor XXS-OV
    EthyleneOxide
    Propylene Oxide
    Ethene
    Propene
    Vinyl Chloride
    Methanol
    Butadiene
    Formaldehyde
    Isopropanol
    Tetrahydrofuan
    1-Chloro-2,3 Epoxypropane
    Styrene
    Methyl Methacrylate
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook

0-200ppm
0-200ppm
0-100ppm
0-100ppm
0-100ppm
0-200ppm
0-100ppm
0-100ppm
0-300ppm
0-200ppm
0-100ppm
0-100ppm
0-100ppm


0.5ppm   6811530 1yr
Draeger X-am® 5000 Organic Vapor-A XXS- OV-A
    Ehtylene Oxide
    Acrylonitrile
    Isobutylene
    Vinyl Acetate
    Ethanol
    Acetaldehyde
    Diethyl Ether
    Acetylene
* Program Sensor to  Gas w/ CC Vision.
* Refer to Sensor Handbook

0-200ppm
0-100ppm
0-300ppm
0-100ppm
0-300ppm
0-200ppm
0-200ppm
0-100ppm


1ppm   6811535 1yr
Draeger X-am® 5000 Ozone XXS- O3 0-10ppm 1ppm 0.1/0.2ppm 6811540 1yr
Draeger X-am® 5000 Phosegene XXS- COCl2 0-10ppm 0.01ppm 0.1/0.2ppm 6812005 1yr
Draeger X-am® 5000 Phosphine XXS- PH3
Draeger X-am® 5000 Phosphine XXS- PHHC
0-20ppm
0-1000ppm
0.1ppm
1ppm
0.1/0.2
50-100ppm
6810866 1yr
6812020 1yr
Draeger X-am® 5000 Sulfur Dioxide XXS- S02 0-50ppm 0.1ppm 2/4ppm 6810885 1yr

 

Draeger X-am® 5000 Specifications-

Dimensions (W x H x D) 1.89" x 5.12" x 1.7" (48 x 130 x 44 mm)
Weight 220-250g
Operating Times > 12 hours with Alkaline and NiMH
> 13 hours with NiMH HC; without Ex Sensor typ
> 250 hours with Alkaline Battery
> 40 hours when using the Save Energy Mode
Charging Times < 4 h
Pump Operation Max. hose length 147.6 feet (45 m)
Alarms Visual = 360°
Audible = Multi-tone > 90 dB at 30 cm
Vibration
Datalogger Can be read out via Infrared > 1,000 hours with 5 gases and arecording interval of 1 value per minute
Protection class IP 67
Air pressure 700 to 1300 mbar 
Air humidity 10 to 95 % r.h.
Temperature -4 to 122 °F (for max. 15 minutes)
Warranty 3 years for the device and CO, H2S, LEL, O2 sensors.
5 years for the E Series Sensors as listed
1 year exotic sensors
1 year for the power supply
Sensors: see DraegerSensor® & Portable Instruments Handbook (below) 
Approvals:
IECEx, ATEX

cCSAus

I M1 Ex da ia I MaII 1G Ex da ia IIC T4/T3 Ga

Class I Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3A/Ex da ia IIC T4/T3 /Ga

 

Draeger X-am® Series Sensor and Warranty Chart-
Draeger X-am® Series Sensor and Warranty Chart

1-5 Gases-
The Draeger X-am® 5000 has the ability to read up to 5 gases at once.

X-Zone Compatible-
The Draeger X-am® 5000 is designed to work with the Draeger X-Zone system for Area Monitoring.

Matrix Display-
The Draeger X-am® 5000 has a easy to read, liquid-crystal display. All gas readings are shown simultaneously and resize automatically depending on the number of sensors installed. When a gas alarm occurs, the reading for the sensor in alarm will be highlighted and will alternate with the alarm level indication of A1 or A2.

High Capacity Battery-
The Draeger X-am 5000 can operate for more than 12 hours with either alkaline batteries or with rechargeable NiMH batteries. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without an Ex sensor installed is typically more than 250 hours.

Long-lasting, reliable sensor technology-
The innovative, catalytic Ex sensor has a high degree of drift stability with a high resistance to silicone and hydrogen sulfide. The sensor boasts an expected service life of more than five years and is extremely sensitive to flammable gases and vapors. Further, the Draeger X-am® 2500 is approved for measuring from methane to nonane,one according to IEC/EN 60079-29-1.

Zone Zero Approved-
The Dräger X-am 5000 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.

Diffusion or Pumped-
An optional external pump with a hose up to 98 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

X-dock compatibility-
The X-am 5000 is compatible with Draeger’s X-dock testing and calibration station. X-dock is Draeger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in 8 to 15 seconds with more than 40 % less gas consumption than competitive instruments. The Draeger X-am 2500 is also compatible with the Draeger Bump Test Station.

Ergonomic and robust - even for the toughest conditions-
The Draeger X-am 5000 is comfortably worn thanks to its low weight and ergonomic design and gas can enter the unit from above and from the front – even if the instrument is inside a pocket or if the front gas entry is accidentally covered. The practical two button control panel and easy menu navigation allow for intuitive operation while the integrated protective rubber coating and sensors not sensitive to shock provide additional safety in case of impacts or vibrations.

Peak value functionality-
The X-am 5000 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the O2 sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.