Draeger X-am® 5800 Multi-Gas Monitors-
The New Draeger X-am® 5800 measures up to six gases and is equipped with a shock-resistant CatEx SR sensor. With the Dräger Gas Detection Connect software, it offers live data transmission and powerful fleet management. Designed for personal monitoring, the X-am 5800 offers the highest level of safety at a low cost of ownership.
X-am 5800 Sensor warranty - 5 years for the : XXS O2 , XXS CO, and XXS H2S. 3 years for the CatEx SR and XXS O2 PR sensor (except NO2 (1 year) and SO2 (2 years))
The X-am 5800 is small and lightweight, comfortable to wear, and easy-to-use, with large buttons for ease of use while wearing gloves. The display clearly shows important information, such as gas readings, alarms and time. The green D-light indicates that the unit is ready for use, with a simple interface. For added safety, the oxygen channel has four alarm thresholds, real pre-alarms, and main alarms for falling and rising concentrations. The X-am 2800 is approved for use in Ex zone 0, and has been tested according to protection class IP 68.
Networking capability provides safety and efficiency: Transfer your recorded data directly and conveniently via Bluetooth to a smartphone and the Gas Detection Connect software. As an alternative, you can also transfer the data directly to the cloud with the X-dock test station, providing secure access to your data and its analysis anytime and anywhere with access to the internet.
The newly-developed CatEx SR sensor calibrates within seconds and protects against shocks, measuring flammable vapors, such as gasoline, diesel, and nonane. The unit can also be set to measure methane, propane, hydrogen, and many other gases. The performance is complemented by Dräger's simple cross calibration concept, in which the measurement gas, calibration gas, and bump test gas can be specified individually. The X-am 5800 calculates the necessary conversations after testing, and the sensor meets the new IEC standard 60079-29-1 (International Electrotechnical Commission) standards.
With decades of experience in sensor technology, Dräger develops and produces the sensors itself, including the powerful and durable electrochemical sensors in the XXS format, resulting in lower operating costs.
Description | Mesuring Range | Measuring Resolution |
Alarm Threshold A1/A2 (standard) | Sensor Order Number & Warranty |
Draeger X-am® 5800 LEL/Combustible Sensors- Catalytic Bead Types - (SR) Shock Resistant. |
||||
Draeger X-am® 5800 - CatEx SR - Methane %Vol Methane only when selected Special Calibrations allowed |
0-100% LEL 0-5.0% Vol CH4 5-100% Vol. CH4 |
1% LEL 0.1% Vol. 1.0% Vol. |
10/20% | 6851900 3yr Warranty |
Draeger X-am® 5800 CO Electrochemical Sensors- | ||||
Draeger X-am® 5800 Carbon Monoxide XXS - CO LC Draeger X-am® 5800 Carbon Monoxide XXS - CO *H2 compensated Draeger X-am® 5800 Dual Channel (Combo) - Carbon Monoxide / Hydrogen Sulfide XXS - CO/H2S LC Draeger X-am® 5800 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC |
0-2000ppm 0-2000ppm CO 0-2000ppm - CO 0-100ppm - H2S 0-2000ppm - CO 0-25% vol - O2 |
1ppm 1ppm CO 1ppm CO 0.1ppm H2S 1ppm CO 1% vol O2 |
35/50ppm-CO 35/50ppm-CO 10/15ppm-H2S 35/50ppm-CO 19.5/23.5% Vol-O2 |
6813210 5yr 6811950 1yr 6813280 2yr 6813275 2yr |
Draeger X-am® 5800 H2S Electrochemical Sensors- | ||||
Draeger X-am® 5800 Hydrogen Sulfide XXS - H2S LC Draeger X-am® 5800 Hydrogen Sulfide XXS - H2S HC Draeger X-am® 5800 Dual Channel (Combo) - Hydrogen Sulfide / Carbon Monoxide XXS - H2S/CO LC Draeger X-am® 5800 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - H2S/O2 LC |
0-100ppm 0-1000ppm 0-100ppm - H2S 0-2000ppm - CO 0-100ppm - H2S 0-25% Vol - O2 |
0.1ppm 2ppm 0.1ppm H2S 1ppm CO 0.1ppm H2S 1% Vol O2 |
10/15ppm-H2S |
6811525 5yr 6812015 1yr 6813280 2yr 6814137 2yr |
Draeger X-am® 5800 O2 Electrochemical Sensors- | ||||
Draeger X-am® 5800 Oxygen XXS - O2 Draeger X-am® 5800 Oxygen XXS - O2 - 100 Draeger X-am® 5800 Oxygen XXS - O2 PR Draeger X-am® 5800 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC Draeger X-am® 5800 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - O2/H2S LC |
0-25% Vol 0-100% Vol 0-25% vol - O2 0-2000ppm - CO 0-25% Vol - O2 0-100ppm - H2S |
0.1% Vol 0.5% Vol 1ppm 0.1% Vol 0.1ppm 0.1% Vol |
19.5/23.5% Vol- O2 19.5/23.5% Vol-O2 35/50ppm- CO 19.5/23.5% Vol-O2 10/15ppm-H2S |
6810881 5yr |
Draeger X-am® 5800 Exotic/Toxic Electrochemical Sensors- | ||||
Draeger X-am® 5800 Amines XXS | 0-100ppm | 1ppm | 10/20ppm | 6812545 1yr |
Draeger X-am® 5800 Ammonia XXS - NH3 | 0-300ppm | 1ppm | 25/50ppm |
6810888 1yr |
Draeger X-am® 5800 Carbon Dioxide XXS - CO2 | 0-5% | 0.1% Vol. | 0.5/1.0 | 6810889 1yr |
Draeger X-am® 5800 Chlorine XXS - Cl2 Chlorine Dioxide ClO2 Bromine Br2 Flourine F2 * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-20ppm | 0.1ppm | 0.5/1.0ppm |
6810890 1yr |
Draeger X-am® 5800 Hydrogen Cyanide XXS - HCN Draeger X-am® 5800 Hydrogen Cyanide XXS - HCN PC |
0-50ppm | 1ppm 0.5ppm |
2.5/4.5ppm 5/10ppm |
6810887 2yr 6813165 1yr |
Draeger X-am® 5800 Hydrogen XXS - H2 Draeger X-am® 5800 Hydrogen XXS - H2 HC |
0-2000ppm 0-4% Vol. |
5ppm 0.1% Vol. |
5/10ppm 0.4/0.8% Vol. |
6812370 1yr 6812025 1yr |
Draeger X-am® 5800 Nitrogen Dioxide XXS - NO2 LC Draeger X-am® 5800 Nitrogen Dioxide XXS - NO2 |
0-50ppm | 0.02ppm 0.1ppm |
1.0/2.0ppm 2.5/5.0ppm |
6812600 1yr 6810884 1yr |
Draeger X-am® 5800 Nitrogen Oxide XXS - NO | 0-200ppm | 1ppm | 15/25ppm | 6811545 1yr |
Draeger X-am® 5800 Mercaptan XXS- CH4S | 0-40ppm | 1ppm | 10/20ppm | 6812535 1yr |
Draeger X-am® 5800 Organic Vapor XXS-OV EthyleneOxide Propylene Oxide Ethene Propene Vinyl Chloride Methanol Butadiene Formaldehyde Isopropanol Tetrahydrofuan 1-Chloro-2,3 Epoxypropane Styrene Methyl Methacrylate * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm 0-200ppm 0-100ppm 0-100ppm 0-300ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm |
0.5ppm | 6811530 1yr | |
Draeger X-am® 5800 Organic Vapor-A XXS- OV-A Ehtylene Oxide Acrylonitrile Isobutylene Vinyl Acetate Ethanol Acetaldehyde Diethyl Ether Acetylene * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-100ppm 0-300ppm 0-100ppm 0-300ppm 0-200ppm 0-200ppm 0-100ppm |
1ppm | 6811535 1yr | |
Draeger X-am® 5800 Ozone XXS- O3 | 0-10ppm | 1ppm | 0.1/0.2ppm | 6811540 1yr |
Draeger X-am® 5800 Phosegene XXS- COCl2 | 0-10ppm | 0.01ppm | 0.1/0.2ppm | 6812005 1yr |
Draeger X-am® 5800 Phosphine XXS- PH3 Draeger X-am® 5800 Phosphine XXS- PH3 HC |
0-20ppm 0-1000ppm |
0.1ppm 1ppm |
0.1/0.2 50-100ppm |
6810866 1yr 6812020 1yr |
Draeger X-am® 5800 Sulfur Dioxide XXS- S02 | 0-50ppm | 0.1ppm | 2/4ppm | 6810885 1yr |
Draeger X-am® 5800 Specifications-
Dimensions (without clip) (W x H x D) | 130 x 48 x 44 mm (5.12 x 1.89 x 1.73 in) |
Weight | typically 220 to 250 g (7.76 to 8.82 oz), depending on sensor equipment |
Operating Times | Approx. 12 h (Bluetooth active) Approx.typical 100 h without Ex-sensor |
Charging Times | < 4 h |
Alarms | 3 LED "red" (gas alarms) 3 LED "yellow" (device alarm) Multi-tone > 90 dB at 30 cm (12 in) |
Datalogger | Application of an optimised data compression method with high accuracy and large storage capacity. (Typically data compression >90 % compared to the traditional data logger concept with adjustable interval) |
Protection class | IP 68 |
Bluetooth® | Bluetooth 5.0 (disabled for some countries outside the EU and outside North America, but can be retrofitted. Contact DrägerService). |
Ready for measurement | < 60 s after switch-on |
Air pressure | 700 to 1300 mbar (Measurement) 800 to 1100 mbar (Use in potentially explosive atmospheres) |
Air humidity | 10 to 95 % r.h. 5 to 95 % r.h. short term |
Temperature | -20 to+50 °C (-4 to 122 F) (Measurement and storage) -40 to+50 °C (-40 to 122 F) (Use in potentially explosive atmospheres) |
Approvals: cCSAus, IECEx, ATEX, CE |
CSA approval: cCSAus Class I, Zone 0, AEx da ia IIC T4 Ga Class I, Div 1, Groups A, B, C, D Class II, Div 1, Gr. E, F, G |
Draeger X-am® Series Sensor and Warranty Chart-
Draeger X-am® Series Sensor and Warranty Chart
Powerful data analysis in the cloud- Networking capability provides safety and efficiency: Transfer your recorded data directly and conveniently via Bluetooth to a smartphone and the Gas Detection Connect software. As an alternative, you can also transfer the data directly to the cloud with the X-dock test station, providing secure access to your data and its analysis anytime and anywhere with access to the internet.
Comfortable Fleet Management- Manage your fleet of equipment comfortably and efficiently with the X-am 5800. Save operating costs and time with fast tests, using the automatic test station X-dock, with low gas consumption or mechanical bump test station. Further advantages include powerful fleet management via our smart software solution, convenient firmware updates in the X-dock, an optional RFID transponder, and individual color marking of the devices. Sensors are durable and devices remain operational for years, with easy-to-replace spare parts, including the power supply. Dräger provides a 4-year manufacturer's warranty on the basic device, and is compatible with X-am 2500 accessories.
Tailor-Made Gas Monitoring- The X-am 5800 is small and lightweight, comfortable to wear, and easy-to-use, with large buttons for ease of use while wearing gloves. The display clearly shows important information, such as gas readings, alarms and time. The green D-light indicates that the unit is ready for use, with a simple interface. For added safety, the oxygen channel has four alarm thresholds, real pre-alarms, and main alarms for falling and rising concentrations. The X-am 5800 is approved for use in Ex zone 0, and has been tested according to protection class IP 68.
Sensors: Durable and Powerful- The newly-developed CatEx SR sensor calibrates within seconds and protects against shocks, measuring flammable vapors, such as gasoline, diesel, and nonane. The unit can also be set to measure methane, propane, hydrogen, and many other gases. The performance is complemented by Dräger's simple cross calibration concept, in which the measurement gas, calibration gas, and bump test gas can be specified individually. The X-am 5800 calculates the necessary conversations after testing, and the sensor meets the new IEC standard 60079-29-1 (International Electrotechnical Commission) standards. With decades of experience in sensor technology, Dräger develops and produces the sensors itself, including the powerful and durable electrochemical sensors in the XXS format, resulting in lower operating costs.
Zone Zero Approved-
The Dräger X-am 5800 has Ex approval for zone 0 for user safety in areas subject to explosion hazard. Additionally, it is not sensitive to electromagnetic radiation, e.g. from wireless devices and is water and dust resistant in accordance with protection class IP 67.
Diffusion or Pumped-
An optional external pump with a hose up to 98 ft long is available for use in tanks and shafts or when searching for leaks. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.
X-dock compatibility-
The X-am 5800 is compatible with Draeger’s X-dock testing and calibration station. X-dock is Draeger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in 8 to 15 seconds with more than 40 % less gas consumption than competitive instruments. The Draeger X-am 5800 is also compatible with the Draeger Bump Test Station.
Focus on Sustainability- During the development of the X-am 5800, sustainability was priority. The durable Dräger sensors and the rechargeable power supply, which can be easily replaced with one screw, ensure a long service life. Almost all spare parts can be replaced by trained users, with remaining parts repaired by Dräger Service. In addition, the X-am 5800 is compatible with accessories from the previous series. Upon request, a reduced number of instructional manuals will be supplied, saving paper, and recycling of old devices is available.
Peak value functionality-
The X-am 5800 can store the highest gas readings for the Ex and toxic gas sensors and the lowest reading for the O2 sensor. These readings can be easily reset after a gas exposure without having to turn the monitor off and on.