Draeger X-am® 8000 -
The Draeger X-am® 8000 was especially designed for clearance measurements and personnel monitoring applications. The 1 to 7 gas detector reliably detects flammable gases such as %LEL (catalytic bead) or IR %LEL / %VOL sensors and vapors as well as O2, CO, H2S, NO, PH3, NO2, HCN, NH3, CO2, Cl2, Clo2, H2, OV, Amine, Oderant, COCl2, Ozone, VOC's (ppm/ppb ranges), and SO2. The innovative signaling design and extensive range of accessories ensure optimum safety and easy handling. Specifically designed to use with a pump, the pump adapter can be removed and the X-am 8000 can be used as a diffusion instrument. Similar in design as the four-gas sensor X-am 3500 series, but as a seven-gas sensor option.
The X-am® 8000 by Draeger was specifically designed for use with an internal pump optimized for clearance measurements. The pump is very powerful and can handle a draw up to 147 feet. The included pump adapter makes it very easy and efficient at switching from a pumped mode to a diffusion mode by simply unscrewing and removing the pump adapter module. This saves enerygy, ensures the pump is only used when needed, reduces wear and tear on the pump and extends the pump life. On startup, the X-am® 8000 has a built in protocol the operator to stall the pump. This is another excellent built in safety feature to ensure the instrument is operating correctly before use.
Benefits-
The X-am 8000 is a specialist for high and low hydrocarbon concentrations. You can fit the X-am 8000 one of two high-performance PID Sensors. Either a PID HC for 0-2000ppm or a PID LC for 0-10ppm and range below 1ppm.
You can also purchase seperately a pre-tube assy for Benzene specific measurements. The meter has a built in function for using the Draeger Benzene tubes for Benzene measurement.
Inductive Charging protects against wear and tear. You can also connect the charging cradles to one another to maximize your table/desk space.
X-DOCK capable. The X-am 8000 series is ready to use the Draeger X-Dock series auto-calibration and bump test station. The X-Dock can be easily put on a network and with the help of the X-Dock Management software sold seperately.
RFID Management. With the optional built in RFID badge, you can easily identify your Draeger X-am 8000 devices in the field for an excellent administration control.
%LEL / %Vol Methane Detection. When measuring for high Methane concentrations you can configure automatic measurement range switching option. If a reading goes higher than say 100% LEL, the display swithes to the range of 0-100% Vol.
Clearance Measurement. The Draeger X-am 8000 has a built in confined space assistant where when activated it calculates the time it takes for the measurement to flow from the end of the probe (FKM Hose) to the unit. Based on parameters such measuring gases, temperature limits, and indicated hose length.
The Draeger X-am 8000 unit also has a clear color code system.
- Red light = gas alarm
- Yellow light = device-related alarm (low battery)
- Green light = device is ready for use
The green glow D-Light allows you to see from a distance whether the unit has been properly tested and ready for use.
Description | Mesuring Range | Measuring Resolution |
Alarm Threshold A1/A2 (standard) | Sensor Order Number & Warranty |
Draeger X-am® 8000 PID Sensors- | ||||
Draeger X-am® 8000 (ppm) PID HC - Isobutene Draeger X-am® 8000 (ppm) PID HC - Benzene |
0-2000ppm 0-1000ppm |
0.1ppm | 50/100ppm | 6813475 1yr Warranty |
Draeger X-am® 8000 (ppb) PID LC - Isobutene Draeger X-am® 8000 (ppb) PID LC - Benzene |
0.05-10ppm 0-5ppm |
10ppb | 5/10ppm | 6813500 1yr Warranty |
Draeger X-am® 8000 LEL/Combustible Sensors- Catalytic Bead and Infrared Types |
||||
Draeger X-am® 8000 - Cat-Ex 125 PR - Methane %Vol Methane only when selected Special Calibrations allowed |
0-100% LEL 0-5.0% Vol CH4 5-100% Vol. CH4 |
1% LEL 0.1% Vol. 1.0% Vol. |
10/20% | 6812950 3yr Warranty |
Draeger X-am® 8000 - Cat-Ex 125 PR - Methane %Vol Methane only when selected Special Calibrations allowed / MSHA Approved |
0-100% LEL 0-5.0% Vol CH4 5-100% Vol. CH4 |
1% LEL 0.1% Vol. 1.0% Vol. |
0.5/1.0% | 6813080 2yr Warranty |
Draeger X-am® 8000 - (IR) Infrared Ex ES %Vol Methane only when selected Vol = -Methane, Ethane, n-Butane Special Calibrations allowed |
0-100% LEL 0-100% Vol |
1% LEL 0.1%Vol. CH4 |
10/20% | 6851881 5yr Warranty |
Draeger X-am® 8000 IR Infrared Sensors- CO2 & Combo CO2/LEL Types |
||||
Draeger X-am® 8000 - (IR) Infrared CO2 ES |
0-9,900ppm |
50ppm CO2 0.02% Vol. CO2 |
0.5/1.0% | 6851882 5yr Warranty |
Draeger X-am® 8000 - Dual IR Ex/CO2 ES - Methane %Vol Methane only when selected Vol = -Methane, Ethane, n-Butane Special Calibrations allowed |
0-100% LEL 0-100% Vol 0-5% Vol CO2 |
1% LEL 0.1%Vol. CH4 0.1%Vol. CO2 or 50ppm CO2 |
10/20% 0.5/1.0% |
6851880 5yr Warranty |
Draeger X-am® 8000 - Dual IR Ex/CO2 HC Methane %Vol Methane only when selected Vol = -Methane, Ethane, n-Butane Special Calibrations allowed *No PID installed with this sensor. |
0-100% LEL 0-100% Vol 0-100% Vol CO2 |
1% LEL 0.1%Vol.CH4 0.1%Vol.CO2 |
10/20% 0.5/1.0% |
6800276 5yr Warranty |
Draeger X-am® 8000 CO Electrochemical Sensors- | ||||
Draeger X-am® 8000 Carbon Monoxide XXS - CO LC Draeger X-am® 8000 Carbon Monoxide XXS - CO Draeger X-am® 8000 Carbon Monoxide XXS-E - CO Draeger X-am® 8000 Carbon Monoxide XXS - CO HC Draeger X-am® 8000 Carbon Monoxide XXS - CO *H2 compensated Draeger X-am® 8000 Dual Channel (Combo) - Carbon Monoxide / Hydrogen Sulfide XXS - CO/H2S LC Draeger X-am® 8000 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC Draeger X-am® 8000 Dual Channel (Combo) - Carbon Monoxide / Hydrogen Cyanide XXS - CO/HCN |
0-2000ppm 0-2000ppm 0-2000ppm 0-10,000ppm 0-2000ppm CO 0-2000ppm - CO 0-100ppm - H2S 0-2000ppm - CO 0-25% vol - O2 0-2000ppm - CO 0-50ppm - HCN |
1ppm 2ppm 2ppm 5ppm 1ppm CO 1ppm CO 0.1ppm H2S 1ppm CO 1% vol O2 1ppm CO 0.1ppm HCN |
35/50ppm-CO 35/50ppm-CO 10/15ppm-H2S 35/50ppm-CO 19.5/23.5% Vol-O2 35/50ppm-CO 2.5/4.5ppm-HCN |
6813210 2yr 6810882 5yr 6812212 5yr 6812010 1yr 6811950 2yr 6813280 2yr 6813275 2yr 6800040 1yr |
Draeger X-am® 8000 H2S Electrochemical Sensors- | ||||
Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S LC Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S Draeger X-am® 8000 Hydrogen Sulfide XXS-E - H2S Draeger X-am® 8000 Hydrogen Sulfide XXS - H2S HC Draeger X-am® 8000 Dual Channel (Combo) - Hydrogen Sulfide / Carbon Monoxide XXS - H2S/CO LC Draeger X-am® 8000 8000 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - H2S/O2 LC |
0-100ppm 0-200ppm 0-200ppm 0-1000ppm 0-100ppm - H2S 0-2000ppm - CO 0-100ppm - H2S 0-25% Vol - O2 |
0.1ppm 1ppm 1ppm 2ppm 0.1ppm H2S 1ppm CO 0.1ppm H2S 1% Vol O2 |
|
6811525 3yr 6810883 5yr 6812213 5yr 6812015 1yr 6813280 2yr 6814137 2yr |
Draeger X-am® 8000 O2 Electrochemical Sensors- | ||||
Draeger X-am® 8000 Oxygen XXS - O2 Draeger X-am® 8000 Oxygen XXS-E - O2 Draeger X-am® 8000 Oxygen XXS - O2 - 100 Draeger X-am® 8000 Dual Channel (Combo) - Carbon Monoxide / Oxygen XXS - CO/O2 LC Draeger X-am® 8000 8000 Dual Channel (Combo) - Hydrogen Sulfide / Oxygen XXS - O2/H2S LC |
0-25% Vol 0-25% Vol 0-100% Vol 0-25% vol - O2 0-2000ppm - CO 0-25% Vol - O2 0-100ppm - H2S |
0.1% Vol 0.1% Vol 0.5% Vol 1ppm 0.1% Vol 0.1ppm 0.1% Vol |
19.5/23.5% Vol- O2 19.5/23.5% Vol-O2 35/50ppm- CO 19.5/23.5% Vol-O2 10/15ppm-H2S |
6810881 5yr |
Draeger X-am® 8000 Exotic/Toxic Electrochemical Sensors- | ||||
Draeger X-am® 8000 Amines XXS | 0-100ppm | 1ppm | 10/20ppm | 6812545 1yr |
Draeger X-am® 8000 Ammonia XXS - NH3 | 0-300ppm | 1ppm | 25/50ppm |
6810888 1yr |
Draeger X-am® 8000 Carbon Dioxide XXS - CO2 | 0-5% | 0.1% Vol. | 0.5/1.0 | 6810889 1yr |
Draeger X-am® 8000 Chlorine XXS - Cl2 Chlorine Dioxide ClO2 Bromine Br2 Flourine F2 * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-20ppm | 0.1ppm | 0.5/1.0ppm |
6810890 1yr |
Draeger X-am® 8000 Hydrogen Cyanide XXS - HCN Draeger X-am® 8000 Hydrogen Cyanide XXS - HCN PC |
0-50ppm | 1ppm 0.5ppm |
2.5/4.5ppm 5/10ppm |
6810887 2yr 6813165 1yr |
Draeger X-am® 8000 Hydrogen XXS - H2 Draeger X-am® 8000 Hydrogen XXS - H2 HC |
0-2000ppm 0-4% Vol. |
5ppm 0.1% Vol. |
5/10ppm 0.4/0.8% Vol. |
6812370 1yr 6812025 1yr |
Draeger X-am® 8000 Nitrogen Dioxide XXS - NO2 LC Draeger X-am® 8000 Nitrogen Dioxide XXS - NO2 |
0-50ppm | 0.02ppm 0.1ppm |
1.0/2.0ppm 2.5/5.0ppm |
6812600 1yr 6810884 1yr |
Draeger X-am® 8000 Nitrogen Oxide XXS - NO | 0-200ppm | 1ppm | 15/25ppm | 6811545 1yr |
Draeger X-am® 8000 Mercaptan XXS- CH4S | 0-40ppm | 1ppm | 10/20ppm | 6812535 1yr |
Draeger X-am® 8000 Organic Vapor XXS-OV EthyleneOxide Propylene Oxide Ethene Propene Vinyl Chloride Methanol Butadiene Formaldehyde Isopropanol Tetrahydrofuan 1-Chloro-2,3 Epoxypropane Styrene Methyl Methacrylate * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm 0-200ppm 0-100ppm 0-100ppm 0-300ppm 0-200ppm 0-100ppm 0-100ppm 0-100ppm |
0.5ppm | 6811530 1yr | |
Draeger X-am® 8000 Organic Vapor-A XXS- OV-A Ehtylene Oxide Acrylonitrile Isobutylene Vinyl Acetate Ethanol Acetaldehyde Diethyl Ether Acetylene * Program Sensor to Gas w/ CC Vision. * Refer to Sensor Handbook |
0-200ppm 0-100ppm 0-300ppm 0-100ppm 0-300ppm 0-200ppm 0-200ppm 0-100ppm |
1ppm | 6811535 1yr | |
Draeger X-am® 8000 Ozone XXS- O3 | 0-10ppm | 1ppm | 0.1/0.2ppm | 6811540 1yr |
Draeger X-am® 8000 Phosegene XXS- COCl2 | 0-10ppm | 0.01ppm | 0.1/0.2ppm | 6812005 1yr |
Draeger X-am® 8000 Phosphine XXS- PH3 Draeger X-am® 8000 Phosphine XXS- PH3 HC |
0-20ppm 0-1000ppm |
0.1ppm 1ppm |
0.1/0.2 50-100ppm |
6810866 1yr 6812020 1yr |
Draeger X-am® 8000 Sulfur Dioxide XXS- S02 | 0-50ppm | 0.1ppm | 2/4ppm | 6810885 1yr |
Draeger X-am® 8000 Specifications-
Dimensions (without clip) (W x H x D) | 7.0" x 3.0" x 1.7" (179 x 77 x 42 mm) |
Weight | Approx. 495 g (17.5 ounces), depending on sensor configuration, without strap, without pump Approx. 550 g (19.4 ounces), depending on sensor configuration, without strap, with pump |
Operating Times | With CatEx and 3 EC sensors Typically 24 hours With IR and 3 EC Sensors Typically 22 hours With 3 EC-sensors Typically 120 hours With IR, PID and 3 EC Sensors Typically 16 Hours With PID Only Typically 42 hours |
Charging Times | Typically 4 hours after use during a shift of max. 10 hours |
Pump Operation | Max. hose length 147.6 feet (45 m) |
Alarms | Visual = 3 LED 'red' (gas alarms), 3 LED 'yellow' (device alarms) Acoustic = Multi-tone, typically 100 dB(A) at 30 cm Vibration |
Datalogger | 12 MB, e.g. at 10 minutes per hour of gas exposure with measuring values changing by the second on all 4 channels: approx. 300 hours |
Protection class | IP 67 |
Air pressure | 700 to 1300 mbar |
Air humidity | 10 to 90% (short-term up to 95%) r.h. |
Temperature | -4°F to 122°F (-20 °C to +50 °C) |
Warranty | 3 years for the device and CO, H2S, LEL, O2 sensors. 1 year exotic sensors 1 year for the power supply Sensors: see DraegerSensor® & Portable Instruments Handbook (below) |
Approvals: IECEx, ATEX cCSAus |
I M1, II 1G Ex da ia I Ma, Ex da ia IIC T4 Ga / Metrological approval pending Class I, Zone 0. ( intrinsically safe ) Class II, Div 1, Gr. E, F, G T4 C22.2 No. 152, ANSI-ISA 12.13.01:2000 |
Draeger X-am® Series Sensor and Warranty Chart-
Draeger X-am® Series Sensor and Warranty Chart
Standard Monitor Includes:
- X-am 8000 unit with specified sensors
- Rechargeable Battery
- Internal Pump and Pump Adapter
- Shoulder Strap
- Inductive Charger and Wall Plug
Monitor with Optional Calibration Kit B adds:
- Standard Accessories
- Calibration Adapter x 1
- 1 each Stainless Regulator
- 1 each 44 Liter of Quad Mix (C0,H2S,LEL and O2) Gas for X-am 8000
Monitor with Optional Calibration Kit B adds:
- Standard Accessories
- Calibration Adapter x 1
- 1 each Stainless Regulator
- 1 each 44 Liter of Quad Mix (C0,H2S,LEL and O2) Gas for X-am 8000
- 1 each 44 Liter of 100 ppm Isobutylene Gas for VOC Sensor
*please note we offer other calibration kits depending upon sensor configuration on monitor - Please call for a custom quote for calibration equipment needed for your selection of sensors. We are an authorized DOT / IATA shipper for calibration gases.