The store will not work correctly when cookies are disabled.
-
Home
-
RKI Replacement H2S Sensor ESR-A13I-H2S for GX-3R Pro
RKI Replacement CO Sensor ESR-A13P-CO for GX-3R Pro
RKI Replacement CO2 Sensor IRR-0409 for GX-3R Pro
RKI Replacement H2S Sensor ESR-A13I-H2S for GX-3R Pro
RKI Replacement H2S Sensor ESR-A13I-H2S for GX-3R Pro -
Part Number |
Description |
ESR-A13I-H2S |
H2S Replacement Sensor |
H2S Safety Data Sheet
Detectable Gases
|
Gas |
Measuring Range (Increments) |
Accuracy Statement |
Preset Alarms |
Sensor Slot 1: Carbon Monoxide (CO) & Hydrogen sulfide (H2S) *Interchangeable |
H2S / CO |
Dual EC |
0 ~ 2000 ppm (1 ppm) |
± 5% of reading or ± 5 ppm CO |
A1: 25 ppm│ A2: 50 ppm │ A3:1200 ppm│TWA: 25 ppm │ STEL: 200 ppm |
0 ~ 200.0 ppm (0.1 ppm) |
± 5% of reading or ± 2 ppm H2S |
A1: 5 ppm│ A2: 30 ppm │ A3: 100 ppm│TWA: 1.0 ppm │ STEL: 5.0 ppm |
H2S Only |
EC |
0 ~ 200.0 ppm (0.1 ppm) |
± 5% of reading or ± 2 ppm H2S |
A1: 5 ppm│ A2: 30 ppm │ A3: 100 ppm│TWA: 1.0 ppm │ STEL: 5.0 ppm |
CO H2 Compensated |
EC |
0 ~ 2,000 ppm |
± 5% of reading or ± 2 ppm CO |
A1: 25 ppm│ A2: 50 ppm │ A3: 1200 ppm│TWA: 25 ppm │ STEL: 200 ppm |
Sensor Slot 2: Combustibles (Methane as standard) |
CH4 / HC |
Catalytic |
0 ~ LEL (1% LEL) |
± 5% of reading or ± 2 % LEL |
1st: 10% LEL │ 2nd: 25% LEL │ 3rd: 50% LEL │ Over:100% LEL |
Sensor Slot 3: Oxygen (O2) |
O2 |
EC |
0 ~ 40.0% Vol. (0.10%) |
± 0.5% O2 |
Low 1: 19.5%│ Low 2: 18.0% │High: 23.5%│ Over: 40.0% |
Sensor Slot 4: Toxics & CO2 *Interchangeable |
HCN |
EC |
0 ~ 30.0 ppm (0.1 ppm) |
± 10% of reading or ± 5 % of full scale |
A1: 5.0 ppm│ A2: 10.00 ppm │ A3: 30.00 ppm│ TWA: 4.7 ppm │ STEL: 10 ppm |
NH3 |
0 ~ 400.0 ppm (0.5 ppm) |
A1: 25.0 ppm │ STEL: 1.0 ppm│ A2: 35.0 ppm│ TWA: 0.30 ppm│A3: 300.0 ppm |
NO2 |
0 ~ 20.00 ppm (0.05 ppm) |
A1: 2.00 ppm│ A2: 4.00 ppm │ A3: 20.00 ppm│ TWA: 0.20 ppm │ STEL: 1.00 ppm |
PH3 |
0 ~ 20.00 ppm (0.01 ppm) |
A1: 0.30 ppm │ STEL: 1.0 ppm │ A2: 0.60 ppm │ TWA: 0.30 ppm │ A3: 0.60 ppm |
SO2 |
0 ~ 100.0 ppm (0.05 ppm) |
A1: 2 ppm│ A2: 5 ppm │ A3: 100 ppm│ TWA: 0.25 ppm │ STEL: 0.25ppm |
CO2 % |
IR |
0 ~ 10.0% Vol. (0.01%) |
± 5% of reading or ± 2 ppm |
A1: 0.50% Vol.│ A2: 3.00% Vol. │ A3: 4.00% Vol.│ TWA: 0.50% Vol. │ STEL: 3.00% Vol. |
CO2 ppm |
0 ~ 10,000 ppm (20 ppm) |
A1: 5,000 ppm│ A2: N/A │ TWA: N/A│STEL: N/A |
Common Specifications
|
Sampling Method |
Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) |
Display |
Full dot LCD with Autobacklight and Autorotation |
Alarm Types |
Gas Alarm |
Trouble Alarm |
- 2 increasing alarms
- STEL
- TWA
- Over scale alarm
- O2 decreasing/
increasing
|
- Sensor disconnection
- Low battery
- Circuit error
- Calibration range error
- Cal or bump due alarm
|
• Man Down Alarm • Panic Alarm |
Display of Alarm |
Gas Alarm |
Trouble Alarm |
- Flashing LED’s
- Continuous buzzer (100 db @ 30cm)
- Flashing gas value
- Vibration
|
- Flashing LED’s
- Intermittent buzzer (95 db @ 30cm)
- Display of error message
|
Operating Temp. & Humidity |
-20°C ~ +50°C [ -4°F ~ +122°F ] 10 to 90% RH, non-condensing (continuous environment) |
-40°C ~ +60°C [ -40°F ~ +140°F ] 0 to 95% RH, non-condensing (temporary environment) |
Response Time |
Within 30 seconds (T90) |
Power Source |
Config |
Li-ion |
Alkaline |
4-gas + EC |
25 hours |
16 hours |
4-gas + EC with Bluetooth |
23 hours |
14 hours |
4-gas + IR |
16 hours |
7 hours |
4-gas + IR with Bluetooth |
15 hours |
6 hours |
Dimension & Weight |
2.9” W x 2.6” H x 1.06” D (Approx. 73 W x 65 H x 26 D mm), 4.58oz (with rubber boot) |
Case Material |
Dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft |
Bluetooth Communication |
BLE: with iOS and Android phone app: RK Link |
Datalogging |
Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Trends |
Standard Accessories |
Alligator clip, protective rubber boot, charger, calibration adapter |
Optional Accessories |
- Padded carrying case
- RP-3R Attachable sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available)
- USB to IrDA downloading cable for datalogger
- SDM-3R calibration station
- Hand aspirator
|
Safety Design / Approvals |
ATEX, CSA, TIIS |
Warranty |
Three years material and workmanship including sensors (1 year for Ammonia sensor)
|