Draeger PAC 6500 Singe Gas Monitor -

The Draeger Pac® 6500 is a non-disposable personal gas detector measures carbon monoxide (CO),
hydrogen sulfide (H2S), sulfur dioxide (S02) or oxygen (O2), reliably and precisely, even in the toughest conditions. The robust design, quick response times, and a replaceable battery to for an unlimited lifetime.

The PAC 6500 is simple two-button operation with overmolded for durability and makes this single gas monitor rugged and versatile. Powerful sensors with a very low t-90 ensure quick responses. The PAC 6500 has a large display / bright backlight and features a loud audible alarm, bright visual and robust vibrating alarms.

Drager PAC-6500 Literature

– Measures carbon monoxide, hydrogen sulfide, oxygen or sulfur dioxide

- Unlimited Operating Time

- Event logger and datalogger recording every measurement and alarm

- Configurable Service Life Indicator

- Rapid functional tests on site using the X-Dock®

- Calculates TWA-TLV and STEL

- Illuminated D-Light shows detector is tested and ready

- Price breaks for orders in quantities of 10/ 50/ 100 / 200 / 500

Draeger PAC 6500 Sensor Specifications

Specifications
Description Mesuring Range Alarm Threshold A1/A2 (standard) Measuring Resolution Response Time Order Number
Draeger PAC 6500 - H2S 0-100ppm 10/15ppm 0.1ppm ≤ 15 seconds 8327613
Draeger PAC 6500 - CO 0-2000ppm 35/50ppm 1ppm ≤ 15 seconds 8327614
Draeger PAC 6500 - O2 0-25%Vol 19.5/23.5 Vol.-% 0.1ppm ≤ 10 seconds 8327616
Draeger PAC 6500 - SO2 0-100ppm 0.5/1ppm 0.1%Vol ≤ 15 seconds 8328274

 

Draeger PAC 6500 Specifications

Dimensions (without clip) (W x H x D) 2.5 x 3.3 x 0.8 in, 64 x 84 x 20 mm
Weight Approx. 3.7 ounces, 106 g (4.0 ounces, 113 g with clip)
Battery service life Min. 2 years (O2 sensors min. 12 months)
Protection class IP68
Air pressure 700 to 1,300 hPa
Air humidity 10 to 90% relative humidity, non-condensing
Temperature -22 °F to 131 °F, -30 °C to +55 °C
(briefly down to -40 °F / -40 °C for 1 hr, depending on sensor)
Approvals:
cCSAus, IECEx, ATEX, CE
Class I, Zone 0, AEx ia IIC T4 Ga, Class II, Division 1, Group E, F, G

 

Draeger PAC Series Sensor and Warranty Chart
Draeger PAC Series Sensor and Warranty Chart

Strong Performance and Maximum Safety -
You can rely on the Draeger Pac 6500: the personal single-gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulfide, sulfide dioxide or oxygen with precision and reliability. Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6500 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.

User Friendly Display with all important information -
The large display clearly indicates the respective gas concentration. Other important information, such as the battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.

Safety in any Situation -
The Pac 6500 is easily handled in even extreme conditions. Depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated. A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.

Easy Handling thanks to clear user guidance -
The D-Light indicates whether functionality of the device has been tested and whether it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 6500 features clearly visible color coding, thereby minimizing the chance of mistakes.

Event Logger -
The Dräger Pac 6500 logs concentrations along with their dates and times. An infrared interface allows them to be loaded onto the PC for further analysis.

360 degree Alarm with various functions -
If the Dräger Pac 6500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time, even if they have been acknowledged. The Pac 6500 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold settings. This provides an additional level of safety as a pre-alarm, in addition to the main alarm, can be set for both oxygen enriched and oxygen deficient atmospheres.

Robust Design - even for the toughest conditions -
The Dräger XXS sensors offer greater safety through extremely fast reaction times. The robust sensors can also be used in extreme environmental conditions without triggering a false alarm.

Fast Function Test Saves Time and Money -
The recommended function tests ensure that the device works flawlessly when performed regularly with a certain gas concentration. Function tests and calibrations can also be carried in the Dräger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The Pac 6500 is simply placed in the bump test station and automatically selects the correct setting.

Economical Operating Costs -
All versions of the Pac 6500 are equipped with extremely durable DraegerSensors and a powerful battery. The Pac 6500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The device is then ready to use again right away.