The Dräger X-zone 5800® pumped model transforms the Dräger personal gas detection instruments X-am 5000, 5100 and 5600 into innovative area monitoring devices for a wide range of applications. A patented combination for increased safety, in addition to the personal air monitors carried on the body, these area monitors are positioned where gas hazards are expected.
State-of-the-art area monitoring: the Dräger X-zone® 5800 in combination with the Dräger X-am® 5000, 5100, and 5600 gas detectors can be used for the measurement of up to six gases. The internal pump and continuous power supply in the explosive area of Zone 0 / C1D1 extend the range of applications in mobile gas detection technology.
Up to 25 Dräger X-zone 5800s can be automatically interconnected to form a wireless fenceline. The interconnection of the area monitoring devices allows for rapid establishment of safety networks for larger areas. A Dräger X-zone 5800 area monitor detecting a gas alarm transmits the alarm signal to all interconnected units. A red flashing alarm in the unit detecting the gas contrasts with alternating red and green flashing alarms of the connected units. This provides simple recognition of alarm status and the actual location of the hazard. With the corresponding configuration, the maximum gas concentration in the monitored area is shown on the display. Combined with the display of the X-zone ID a clear containment of the hazard area is possible.
The 24 Ah battery of the Dräger X-zone 5800 provides up to 120 hours of continuous operation – up to a complete working week.
Dimensions (W x H x D) | 490 x 300 x 300 mm 20 x 12 x 12 in. |
Weight | 10 kg (22 lbs.) (24 Ah battery) |
Ambient conditions | Temperature max. +50 °C; max. 122 °F Pressure 700 to 1,300 hPa Humidity 10 to 95 % r.h. |
Ingress Protection | IP67 |
Alarm | Visual 360° LED (illuminated ring) Audible 360°; >108 dB in a distance of 1 m (3 ft.), 120 dB in a distance of 30 cm (1 ft.) Configurable alarm patterns, frequencies and volumes |
Life signal | Green status display (360°), illuminated ring (LED) |
Operating time | Approx. 120 h (24 Ah battery) Depending on sensor equipment / configuration of the life signal |
Charging time | Approx. 14 h Flexible power supply: External 100 – 240 V charger (worldwide) or inductive wireless charger |
Pump operation | Maximum hose length: 45 m (150 ft.), 30 m (98 ft.) for zone 0 |
Alarm output | Potential-free alarm contact for intrinsically safe circuits (6-pole); <20 V to 0.25 A (0.15 A constant current); Resisting load |
Radio transmission | Worldwide license-free ISM frequencies Digital radio, robust and interference-free transmission up to 100 m (328 ft.) |
RF approvals | 868 MHz (EU, Norway, Switzerland), 915 MHz (USA, Canada, Singapore, Australia), 433 MHz (Russia) |
Approvals | ATEX I M1 Ex ia I Ma II 1G Ex ia IIC T3 Ga II 2G Ex ia d IIC T4 Gb IECEx Ex ia IIC T3 Ga Ex ia d IIC T4 Gb Ex ia I Ma CSA/US Class I, zone 0, A/Ex ia IIC T3 /Ga Class I, zone 1, A/Ex ia d IIC T4 /Gb |
Features: