The TracXP TXP-T40 transmitter is a highly configurable fixed gas detector supporting single or dual sensor applications in Class 1 Division 1 or Class 1 Division 2 environments. Local and remote sensor options allow the TXP-T40 to adapt to a wide variety of industrial applications.
Size | 5”(L) x 5.4”(W) x 8”(H) Aluminum Housing 4”(L) x 5”(W) x 7”(H) Poly Housing |
Shipping Weight | 6.5 lbs. (3 k.) Aluminum Housing 3 lbs. (2 k.) Poly Housing |
Power Supply | 10-30 VDC at < 10 watts with relay board (all relays energized) |
Input | Channel 1 & 2: Electrochemical, Catalytic Bead, Infrared sensor |
Standard Output | Dual 3-wire 4-20mA current source, (Max loop Resistance 600 ohms @ 24VDC, Ethernet R-45 with built-in web Server, Modbus® TCP) |
Optional Output | Three programmable relays plus dedicated FAULT relay Dual programmable master / slave Modbus® RS-485 serial interfaces |
Display | QVGA backlit color TFT 320x240 |
Temperature | -40°F to 140°F (-40°C to +60°C) *See Sensor Limitations |
Humidity |
IR Sensor: RH Non-condensing 95% Electrochemical Sensor: RH Non-condensing 85% |
IP Rating | Cast Aluminum Enclosure: IP65 w/88-C200-0002-00 or 88-C200-0003-00 Black Poly Enclosure: Suitable for IP54 |
Approvals | Cast Aluminum Enclosure: Explosion-Proof Cl.1 Div.1 Gr ABCD w/88-C200-0002-00 Sensor Housing Non-Incendive Cl.1 Div.2 Gr ABCD w/88-C200-0002-00 or 88-C200-0003-00 Sensor Housing CSA Black Poly Enclosure: Non-Incendive Cl.1 Div.2 Gr ABCD** |
Part Number | Description |
88-1309-0000-30 | TXP-T40 REMOTE SENSOR ASSEMBLY, POLYCARBONATE, C1D2 NON-INCENDIVE |